Campbell Hausfeld Attach it to this manual or file it for safekeeping. IN626701AV Operating Instructions And Parts Manual

Oilless compressor
Table of Contents

Advertisement

Available languages

Available languages

See Warranty on page 8 for important information about commercial use of this product.
Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Oilless compressors are designed for
do-it-yourselfers with a variety of
home and automotive jobs. These units
operate without oil. Compressed air
from this unit will contain moisture.
Install a water filter or air dryer if
application requires dry air.

Safety Guidelines

This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates an
imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates a
potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make sure
to tighten fittings, bolts, etc., before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance.
© 2010 Campbell Hausfeld/Scott Fetzer
STOP!
Record the Model No., Serial No. and date
of purchase located on the base below the
pump in the space below.
Model No. _______________________
Date Code _______________________
Date of purchase _________________
Retain these numbers for future reference.
Have the date code, model number,
and parts list (with missing parts circled
before calling.)
shipping, handling or use. Damage may
result in bursting and cause injury or
property damage.
General Safety Information
CalIFOrnIa PrOPOSItIOn 65
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
General SaFety InFOrMatIOn
Since the air compressor and other
components used (filters, lubricators,
hoses, etc.), make up a high pressure
pumping system, the following safety
precautions must be observed at all
times:
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.chpower.com
Oilless
Compressors
DO nOt retUrn the
PrODUCt tO the
retaIler! Call
1-800-543-6400
Do not operate unit
if damaged during
This product or
its power cord may
FP209800

Breathable Air Warning

This compressor/pump is not
equipped and should not be used "as
is" to supply breathing quality air.
For any application of air for human
consumption, the air compressor/
pump will need to be fitted with
suitable in-line safety and alarm
equipment. This additional equip-
ment is necessary to properly filter
and purify the air to meet minimal
specifications for Grade D breath-
ing as described in Compressed Gas
Association Commodity Specification
G 7.1 - 1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards Associa-
tions (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air ap-
plication and proper in-line safety
and alarm equipment is not simul-
taneously used, existing warranties
shall be voided, and Campbell Haus-
feld disclaims any liability whatso-
ever for any loss, personal injury or
damage.
1. Read all manuals included
with this product
carefully. Be thoroughly
familiar with the controls
and the proper use of the
equipment.
2. Follow all local electrical and
safety codes as well as in the US,
National Electrical Codes (NEC) and
Occupational Safety and Health Act
(OSHA).
IN626701AV 3/10
MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Campbell Hausfeld Attach it to this manual or file it for safekeeping. IN626701AV

  • Page 1: Breathable Air Warning

    In case of questions, damaged or missing parts, please call 1-800-543-6400 for customer assistance. REMINDER: Keep your dated proof of purchase for warranty purposes! © 2010 Campbell Hausfeld/Scott Fetzer Oilless Compressors DO nOt retUrn the PrODUCt tO the...
  • Page 2: Spraying Precautions

    Oilless Compressors General Safety Information (Continued) 3. Only persons well acquainted with these rules of safe operation should be allowed to use the compressor. 4. Keep visitors away and NEVER allow children in the work area. 5. Wear safety glasses and use hearing protection when operating the pump or unit.
  • Page 3: Operation

    Installation (Continued) 2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire. Never connect green (or green and yellow) wire to a live terminal.
  • Page 4: Maintenance

    MOIStUre In COMPreSSeD aIr Moisture in compressed air will form into droplets as it comes from an air compressor pump. When humidity is high or when a compressor is in continuous use for an extended period of time, this moisture will collect in the tank.
  • Page 5 FP209800 notes www.chpower.com...
  • Page 6: Troubleshooting Chart

    Oilless Compressors troubleshooting Chart Symptom Possible Cause(s) Compressor will not run 1. Switch in OFF position 2. No electrical power at wall outlet 3. Compressor has reached automatic shut- off pressure 4. Motor overheated 5. Loose electrical connection 6. ON / OFF switch bad 7.
  • Page 7: Replacement Parts List

    Please provide following information: - Model number - Serial number (if any) - Part description and number as shown in parts list Address parts correspondence to: Campbell Hausfeld Attn: Customer Service 100 Production Drive Harrison, OH 45030 U.S.A. replacement Parts list ref.
  • Page 8: Limited Warranty

    8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options. Freight costs must be borne by the purchaser. C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
  • Page 9: Proposition 65 De Californie

    MÉMENTO : Gardez votre preuve datée d’achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2010 Campbell Hausfeld/Scott Fetzer Compresseur Sans huile ne PaS renVOyer le PrODUIt aU MarChanD ARRÊT!
  • Page 10: Précautions De Pulvérisation

    Compresseur Sans Huile Généralités sur la Sécurité Suite 3. Seules les personnes bien familiarisées avec ces règles d’utilisation doivent être autorisées à se servir du compresseur. 4. Garder les visiteurs à l’écart de/et NE JAMAIS permettre les enfants dans l’endroit de travail. 5.
  • Page 11 Installation ( Suite 2. Si la réparation ou le remplacement du cordon ou de la fiche est nécessaire, ne pas connecter le fil de terre à ni une ni l’autre borne plate. Le fil avec l’isolation qui a une surface externe verte (avec ou sans rayures) est le fil de terre.
  • Page 12: Entretien

    Compresseur Sans Huile Fonctionnement ( Suite aVant ChaQUe DéMarraGe - PrOCéDUre De FOnCtIOnneMent 1. Tourner l’interrupteur à la position « OFF » ARRÊT ( O ) et brancher le cordon d’alimentation. 2. Tourner le bouton du régulateur dans le sens antihoraire pour fermer le débit d’air.
  • Page 13 entretien ( Suite 3. En portant des lunettes de sécurité, vidanger l’air du réservoir en tirant l’anneau de la soupape de sécurité. À l’aide de l’autre main, détourner l’air se déplaçant rapidement, pour protéger le visage. notes 4. Vidanger le réservoir de toute condensation en ouvrant le robinet de vidange au fond du réservoir.
  • Page 14: Guide De Dépannage

    Compresseur Sans Huile Guide de Dépannage Symptôme Cause(s) Possible(s) Le compresseur ne 1. Interrupteur en position “OFF” (arrêt). fonctionne pas. 2. Aucun courant à la prise de courant murale 3. Le compresseur a atteint la pression d’arrêt automatique 4. Moteur surchauffé 5.
  • Page 15: Liste De Pièces De Rechange

    - Numéro du modèle - Numéro de série (si applicable) - Description de la pièce et son numéro sur la liste de pièces Correspondance concernant les pièces : Campbell Hausfeld Attn: Customer Service 100 Production Drive Harrison, OH 45030 U.S.A.
  • Page 16: Garantie Limitée

    8. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE : A. Fournir une preuve d’achat datée et un état d’entretien. B. Appelez Campbell Hausfeld (800-543-6400) pour obtenir vos options de service sous garantie. Les frais de transport sont la responsabilité de l’acheteur.
  • Page 17: Proposición 65 De California

    1-800-543-6400 para obtener ayuda. RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! © 2010 Campbell Hausfeld/Scott Fetzer Compresores Sin aceite ¡nO DeVUelVa el PrODUCtO al...
  • Page 18: Precauciones Para Rociar

    Compresores Sin Aceite Informaciones Generales de Seguridad ( Continuación 2. Siga todos los códigos de seguridad laboral y electricidad establecidos en su país, por ejemplo los de la NEC y OSHA en EUA. 3. Este compresor sólo debe ser usado por personas que estén bien familiarizadas con las reglas de seguridad y de manejo.
  • Page 19: Términos Y Definiciones

    Instalación ( Continuación 2. Si necesita reparar o reemplazar el cordón o el enchufe, no conecte el cable de conexión a tierra a ninguno de los terminales planos. El alambre cuya superficie externa del aislante es verde, con o sin rayas amarillas, es el cable de conexión a tierra.
  • Page 20: Procedimiento De Encendido

    Compresores Sin Aceite Funcionamiento Continuación anteS De InICIar CaDa PrOCeDIMIentO De enCenDIDO 1. Coloque el interruptor en OFF ( O ) y conecte el cordón al tomacorrientes. 2. Gire la perilla del regulador en sentido antihorario para cerrar el flujo de aire. 3.
  • Page 21 FP209800 notas 21 Sp...
  • Page 22: Guía De Diagnóstico De Averías

    Compresores Sin Aceite Guía de diagnóstico de averías Problema Posible(s) Causa(s) El compresor no funciona 1. El interruptor está en la posición OFF (apagado) 2. No hay corriente eléctrica en el tomacorriente de la pared 3. El compresor alcanzó la presión de corte automático 4.
  • Page 23 Sírvase darnos la siguiente información: - Número del modelo - Número de Serie (de haberlo) - Descripción y número del repuesto según la lista de repuestos Puede escribirnos a: Campbell Hausfeld Attn: Customer Service 100 Production Drive Harrison, OH 45030 U.S.A. lista de repuestos no.
  • Page 24: Garantía Limitada

    1. DURACION: A partir de la fecha de compra por el comprador original tal como se especifica a continuación: Un año. 2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400 3.

This manual is also suitable for:

Fp209800

Table of Contents