3
Orientation of the Cleaning Belt
Mount the fixing cleaning belt as shown .
Orientation of the fixing Upper/
4
Lower Solenoid
Adjust the position so that the stroke [A]
is 3 ± 0.2 mm for the fixing paper solenoid and
4 ± 0.2 mm for the lower fixing solenoid.
CHAPTER 2 STANDARDS AND ADJUSTMENTS
Figure 2-49 Fixing Upper Cleaning
Belt (rear view)
Figure 2-50 Fixing Lower Cleaning
Belt (rear view)
Figure 2-51
2-25