When exchanging the capacitor case and main PCB assy, perform the
following steps after completing reassembly.
Capacitor Case Rank Setting Procedure
(1) Turn the power switch ON while holding the MODE key.
(2) Press the MODE key for 10 seconds until the LCD unit displays "<<Ver **.**>>".
.
: Program version No.
[[
[[
(3) Press the SET key, and the LCD unit displays "N =
: Total number of printing times (light emission times of xenon lamp)
[[[[[
(4) Press the SET key, and the LCD unit displays "C-BOX RANK =
(5) Check the rank printed on the capacitor box.
The capacitor case rank is printed at the bottom of the case.
Example)
8E29 11000 D
(6) Set the capacitor case rank according to the printed rank by pressing the
MODE key.
The rank display changes in the following sequence as the MODE key is
pressed.
(7) Press the SET key.
This completes the setting of the capacitor case rank and the machine is reset.
Rank (A to J)
Capacitance
Mf g. No.
III - 73
.
[[[[["
["
Current setting