Remove the retaining rings, pull out the two outer plate shafts, and remove the
outer plate, the lock plate, and the two return springs.
Remove the two screws to remove the sensor bracket.
Remove the two magazine springs, and the magazine lift sub assy while pressing
parts A and B of the film path to release them, as shown in Fig. 3.45.
Magazine lift
sub assy
A
Magazine springs
Screw
B
Outer plate shafts
Fig. 3.45
III - 34
Screw
Sensor bracket
Retaining ring
Film path
Lock plate
Outer plate
Retaining ring
Return spring
Return spring