5.0 Introduction

Correct hardware adjustments, regular maintenance, and calibrations will ensure
continued peak printer performance.

5.1 Media Sensor Adjustment

The laterally adjustable Media Sensor is used to detect media; it also detects
label TOF for all media types, except continuous stock (where TOF is
determined by the label format). To properly detect TOF, the gap, notch, or
black mark must pass under the Sensor Eye Mark, as noted in the table below. If
messages such as "Out-Of-Stock" or "Top-Of-Form" appear, the sensor's
position may need adjustment.
Media Type*
Standard die-cut
Circular die-cut
Notched
Reflective
Continuous
*See Section 1.3.2 for an explanation of the media requirements.
To adjust the Media Sensor:
n
The printer powered 'On', media loaded, and the access cover open, rotate
the Printhead Latch forward to raise the printhead.
o
After ensuring that the media is passing through the Media Sensor, position
the Sensor Eye Mark over the label's TOF mark (see drawing next page) by
grasping and moving the Slide Tab 'in' or 'out'.
(Continued next page)
Media Sensor Adjustment
Selected Sensing Method
Gap
Gap
Gap
Reflective
Continuous
Sensor Eye Mark Position
Near the middle of the label
Directly over the apex
Directly over the notch
Directly over the black mark
Near the middle of the label
49