Download Print this page

Step 1 Ventilation Requirements - Thermador PRD366EG Installation Instructions Manual

Professional pro-grand dual fuel ranges
Hide thumbs Also See for PRD366EG:

Advertisement

Available languages

Available languages

Step 1 Ventilation Requirements
It is strongly_ recommended
that a
suitable exhaust
hood be installed
above
the
range.
Downdraft
ventilation
should notbe used. The
table
below
indicates
the
Thermador
hoods,
by
model
number,
that are recommended
for use with all ranges.
1. Select
Hood and
BNower Modems:
For wall installations,
the hood
width
must,
at a minimum,
equal
the width
of the range
cooking surface. Where space
permits,
a hood larger in width
than the cooking
surface
may
be desirable
for improved ven-
tilation performance.
For
island
installations,
the
hood width should,
at a mini-
mum,
overhang
the
range
cooking
surface by 3" on each
side.
Ventilation
hoods and blowers are
designed
for use with single wall
ducting.
However,
some
local
building
codes or inspectors
may
require double wall ducting.
Con-
sult local
building
codes
and/or
local agencies,
before starting, to
assure that hood and duct instal-
lation will meet local requirements.
2_
Do not install a microwave
oven /
ventilator
combination
above the
3.
range, as these types of units do
not provide
the proper ventilation
and are not suitable
for use with
the range.
Hood
Placement:
For best smoke
elimination,
the lower
edge of the hood
should be installed
36" above
the
range
cooking
surface.
(See Fig. 1).
If the hood contains
any com-
bustible materials
(i.e. a wood
covering),
it must be a mini-
mum of 36" above the cooking
surface.
Consider
Make-Up
Air:
Due tothe high volume of ven-
tilation air, a source of outside
replacement
air
is recom-
mended.
This
is particularly
important for tightly sealed and
insulated
homes.
A qualified
heating
and venti-
lating
contractor
should
be
consulted.
30" RANGE
36" RANGE
48" RANGE
VTRI030D,
PH30CS,
VTR1530D,
PHE30 / 36
orVTNI030C
VTR1030D
HNW36YS
orVTRI530D
PH36CS / 42CS
PH E36 / 42
HNW36YS / 42YS
PH48CS / 54CS
PHE48 / 60
VTR1030D,
VTR1530D,
orVTNI030C
VTRI030D
or VTR1530D
VTR1030D,
VTR1530D,
orVTNI030C
HNW48YS
VTR1030D
orVTRI530D
HNI42YS
VTR1030D,
HTNI42YS
orVTR1530D
HNI42YS
VTRI030D,
HTNI42YS
orVTRI530D
HTNI48YS / 54YS
HTN N8YS / 54YS
VTR1530D
Notes:
* For wall installations
where
adequate
space is available,
the installer
or user may elect to
use a hood that is wider than the rangetop
cooking
surface.
This may be particularly
beneficial
for installations
having
a long duct run or when heavy usage of the grill is anticipated,
in which
improved
capturing
of the cooking
exhaust
is desired.
•* Thermador
offers a choice of remote (VTR1030D
or VTR1530D)
or internal
(VTN1030C)
blowers
for use in wall installations.

Advertisement

loading