Step 1: Ventilation
Requirements
It is stron Ig!y.recommended
that a
suitable exhaust
hood be installed
above
the
range.
Downdraft
ventilation
should notbe used. The
table
below
indicates
the
Thermador
hoods,
by
model
number,
that are recommended
for use with all ranges.
1. Semect Hood and
BNower Models:
Forwall
installations,
the hood
width
must,
at a minimum,
equal the width
of the range
cooking
surface.
Where
space permits,
a hood larger
in width than the cooking
sur-
face may be desirable
for im-
proved
ventilation
perfor-
mance.
For
island
installations,
the
hood width should,
at a mini-
mum,
overhang
the
range
cooking surface by 6" on each
side.
Ventilation
hoods and blowers are
designed
for use with single wall
ducting.
However,
some
local
building
codes or inspectors
may
require double wall ducting.
Con-
suet local
building
codes
and/or
local agencies,
before starting, to
assure that hood and duct instal-
lation will meet local requirements.
Hood
blower
speeds
should
be variable
to reduce
noise
and loss of heated or air con-
ditioned
household
air when
maximum
ventilation
is not
required.
Normally,
the maxi-
mum
blower
speed
is only
required
when using the grill.
2_
Hood
P acement:
For best smoke elimination,
the
lower edge of the hood should
be installed a minimum
of 30" to
a maximum
of 36" above
the
range
cooking
surface.
(See
Fig. 1).
If the hood contains
any com-
bustible
materials
(i.e. a wood
covering),
it must
be a mini-
mum of 36" above the cooking
surface.
Consider
Make-Up Air:
Due to the high volume of venti-
lation
air, a source
of outside
replacement
air
is recom-
mended.
This is particularly
im-
portant
for tightly
sealed
and
insulated
homes.
A qualified
heating and ventilat-
ing contractor
should
be con-
suited.
30" RANGE
36" RANGE
48" RANGE
PH30ZS
PH30HQS
PHE30,36
PH36ZS, 42ZS
PH E36,42
HNW36YS
HNW42 YS
VTR1000Q,
VTR1400Q
ORVTN 1000Q
VTR1000Q, VTR1400Q
orVTN 1000Q
HTNI42YS
VTRI000Q,
HNI42YS
VTR1400Q
PHI48ZS
HTNI42YS
VTR1000Q
HNI42YS
VTR1400Q
VTR1000Q, VTR1400Q
VTR1000Q,VTR1400Q
PH48ZS
VTR1000Q
PH48HQS
VTR1400Q
PH E48,60
orVTN 1000Q
PHI48ZS
HTNI48YS
HNI48YS
HTNI54YS
HNI54YS
PHI60ZS
VTR1400Q
Notes:
* For wall installations
where
adequate
space is available,
the installer or user may elect to
use a hood that is wider than the range cooking
surface.
This may be particularly
beneficial
for those cases, such as a long duct run or heavy usage of the grill, in which improved
capturing
of the cooking exhaust
is desired.
•* Thermador
offers a choice of remote (VTR1000Q
or VTR1400Q)
or in-hood
(VTN 1000Q) blowers
for use in wall installations.

Advertisement