Step 5
Gas Requirements and Hookup
Verify the type of gas being used atthe installation
site.
The appliance
is shipped
from the factory
for use
with natura_ gas. it must be converted
for use with
propane.
A quamified technician
or installer
must
do the conversion.
Make certain the range matches
the type of gas available
at this location.
The field
conversion
kit for this series
of dual-fuel
ranges is Thermador
Model PLPKIT.
Obey all instruc-
tions
in PLPKIT
for correct
conversion
of the gas
regulator
and settings for the gas valves.
CAUTION
When
connecting
unit to propane
gas,
make
certain the propane gas tank is equipped
with its
own high pressure
regulator
in addition
to the
pressure
regulator
supplied
with the appliance.
The pressure
of the gas supplied
to the appli-
ance
regulator
must
not
exceed
14"
(34.9 mb) water column.
This appliance
has been CSA certified for safe opera-
tion up to an elevation
of 10,200 ft. without
any modi-
fications.
Exception:
For use with propane,
the appli-
ance must be converted
per the LP conversion
in-
structions.
Natural
Gas Requirements:
Inlet Connection:
3/4" NPT
Supply
Pressure:
Manifold
Pressure:
external
1/2" NPT internal
(Minimum
314" diam. flex line.)
6" min. to 14" max. water col-
umn.
(14.9 to 34.9 mb)
5" water column
(12.5 mb)
Propane
Gas Requirements:
Inlet Connection:
3/4" NPT external
1/2" NPT internal
(Minimum
3/4" diam. flex line.)
Supply
Pressure:
11" min. to 14" max. water col-
umn.
(27.4 mb to 34.9 mb)
Manifold
Pressure:
10" water column
(24.9 mb)
Gas line must not come in contact
with any components
inside back
cover
of range.
Run
gas
line in
channel
in back of range.
HOOK
UP
A manual
gas shut-off
valve
must be installed
external to the appliance,
in a location accessible
from the front, for the purpose
of shutting
off the
gas supply. The supply line must not interfere with
the back of the unit. Make sure the gas supply is
turned
off at the manual
shut-off
valve
before
connecting
the appliance.
The range is supplied
with its own pressure
regu-
lator that has been permanently
mounted
within
the range body.
Use 3/4" flex line to connect
between
the gas
supply
and the appliance
manifold
pipe, which
exits the upper rear of the appliance.
The appli-
ance manifold
pipe connection
has a 3/4" NPT
external
thread
and a 1/2" NPT internal
thread.
(See Photo A.) Use caution to avoid crimping the
3/4" flex line when making bends.
The gas supply connections
shaft be made by a
competent
technician
and in accordance
with
local codes or ordinances.
In the absence
of a
local code, the installation
must conform
to the
National
Fuel Gas Code ANSI Z223.1iNFPA54-
current
issue.
Always
use pipe sealing
compound
or Teflon _
tape on the pipe threads,
and be careful
not to
apply
excessive
pressure
when
tightening
the
fittings.
Leak testing
of the appliance
shall be in accor-
dance with the following
instructions.
• Turn on gas and check supply line connections
for leaks using a soap and water solution.
Bubbles
forming
indicate
a gas leak. Repair all
leaks immediately
after finding
them.
Do not use a flame
of any kind to check
for
gas leaks.
Photo
A
Channel
forgas
line
Use 3/4" flex line to connect
between
the gas
supply
and the appliance
manifold
pipe, which
exits the upper rear of the appliance.
12