Step 6: Electrical Requirements, Connection & Grounding
A 3- or 4-conductor
supply may be connected
to the
terminal
block.
3-WIRE
LEAD CONNECTION
1.
Remove
upper nuts only from the terminal
block
studs. Do not remove
nuts which
secure
range
interna_
wiring
_eads.
2.
Secure
the neutral,
grounded
wire of the supply
circuit, to the center stud of the terminal
block with
nut. (See Fig. 10).
3.
Secure the LI (black) and L2 (red) power leads to
the outside
terminal
block studs (brass colored)
with nuts.
4.
Tighten
nuts securely,
4-WIRE CONNECTION
.
.
.
Remove
upper nuts only from the terminal
block
studs.
Do not
remove
lower
nuts
which
sen
cure
range
internal
wiring
_eads.
Remove
ground
strap screw and bend the strap
up as shown in Fig. 11.
Secure
the neutral wire to the center stud of the
terminal
block with nut.
4.
Secure the LI (black) and L2 (red) power leads to
the outside
terminal
studs
(brass
colored)
with
nuts.
.
Secure the bare copper ground lead to the range
chassis
using the ground screw previously
used
for the ground
strap.
Be sure that neutral
and
ground terminals
do not touch.
6.
Tighten
all connections
securely.
F_G. 9
FIG. 10
Conductor
Securement
Upper Nut
!pply Wire
Flat Washer
3 Wire Connection
LI Black
F_G.11
Ground Strap
L2 Red
Neutral White
LI Black'_
Red
15