Step 1 Ventilation Requirements - Thermador PG36 Series Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Step 1 Ventilation Requirements
It is strong!2: recommended
that a
suitable exhaust
hood be installed
above
the
range.
Downdraft
ventilation
should
not be used.
The
table
below
indicates
the
Thermador
hoods,
by
model
number,
that are recommended
for use with all ranges.
1. Select Hood and
BNower Modems:
Forwall
installations,
the hood
width
must,
at a minimum,
equal the width
of the range
cooking surface. Where space
permits, a hood larger in width
than the cooking surface
may
be desirable for improved ven-
tilation performance.
For
island
installations,
the
hood width should,
at a mini-
mum,
overhang
the
range
cooking surface by 6" on each
side.
Ventilation
hoods and blowers are
designed
for use with single wall
ducting.
However,
some
local
building
codes or inspectors
may
require double wall ducting.
Con-
sult local
building
codes
and/or
local agencies,
before starting, to
assure that hood and duct instal-
lation will meet local requirements.
Hood
blower
speeds
should
be variable
to reduce
noise
and loss of heated or air con-
ditioned
household
air when
maximum
ventilation
is not
required.
Normally,
the maxi-
mum blower speed is only re-
quired when using the grill.
2_
Hood Placement:
For best smoke
elimination,
the lower
edge
of the
hood
should be installed a minimum
of 30" to a maximum
of 36"
above the range cooking
sur-
face. (See Fig. 1).
If the hood contains
any com-
bustible
materials
(i.e. a wood
covering),
it must be a mini-
mum of 36" above the cooking
surface.
3_
Consider
MakeoUpAir:
Due to the high volume of ven-
tilation air, a source of outside
replacement
air
is recom-
mended.
This
is particularly
important for tightly sealed and
insulated
homes.
A qualified
heating
and venti-
lating
contractor
should
be
consulted.
30" RANGE
36" RANGE
48" RANGE
PH30ZS
PH30HQS
PHE30,36
PH36ZS, 42ZS
PHE36,42
HNW36YS
HNW42 YS
VTRI000Q,
VTR1400Q
OR VTN 1000Q
VTRI000Q,
VTR1400Q
or VTN 1000Q
HTNI42YS
VTRI000Q,
HNI42YS
VTR1400Q
PHI48ZS
HTNI42YS
VTRI000Q
HNI42YS
VTR1400Q
VTRI000Q,
VTR1400Q
VTRI000Q,
VTR1400Q
PH48ZS
VTRI000Q
PH48HQS
VTR1400Q
PHE48,60
or VTN 1000Q
PHI48ZS
HTNI48YS
HNI48YS
HTNI54YS
HNI54YS
PHI60ZS
VTR1400Q
Notes:
* For wall installations
where adequate
space is available,
the installer
or user may elect to
use a hood that is wider than the range cooking
surface.
This may be particularly
beneficial
for those cases, such as a long duct run or heavy usage of the grill, in which improved
capturing
of the cooking
exhaust
is desired.
•* Thermador
offers a choice of remote
(VTR1000Q
or VTR1400Q)
or in-hood
(VTN 1000Q)
blowers for use in wall installations.