Step 6: Electrical Requirements, Connection & Grounding
Prior to installing
appliance,
always
disconnect
appliance
electrical
supply cord, if so equipped,
from wall receptacle.
If appliance
is hard-wired
to
power supply, disconnect
power to unit by turning
off the proper circuit breaker or disconnecting
the
proper fuse. Lock service panel to prevent power
from being turned
ON accidentally.
Dual Fuel range models can be connected
or hard-
wired to the power supply as described
on Page 15.
Chart
B: Electrica_
SuppJy
Circuit
Requirements
MODEL TYPE
VOLTAGE
CURRENT
30"
240/208 VAC
35 Amps
36"
240/208 VAC
35 Amps
48"
240/208 VAC
50 Amps
FREQUENCY
PHASE
60 Hz.
Single
60 Hz.
Single
60 Hz.
Single
A neutral
supply wire must be provided
from the
power source (breaker/fuse
panel) because
criti-
cal range
components,
including
the
surface
burner spark re-ignition
module, require 120 VAC
to operate
safely and properly. An improper
120/
240 VAC power
supply will cause
malfunction,
damage
tMs appliance,
and possibly
create
a
condition
of shock
hazard.
If the correct
power
supply circuit is not provided,
it is the responsibil-
ity and obligation
of the installer and user to have
proper
power
supply
connected.
This must be
accomplished
in accordance
with all appficable
local codes and ordinances
by a qualified
electrk
cian.
In the absence
of local codes
and ordk
nances,
the power supply connection
shall be in
accordance
with the National
Electric Code.
Observe
all governing
codes
and ordinances
when grounding.
In the absence
of these codes
or ordinances
observe
National
Electrical
Code
ANSIiNFPA
No. 70 current issue. See Pages 15
and 16 for grounding
method,
Electrical
wiring diagrams
and schematics
have
been placed in the toe kick area of the range for
access
by a qualified
service
technician,
The ranges
are to be connected
to a 240/208
VAC power supply.
CAUTION
The appliance
must be isolated from the gas supply piping system by closing its individual
manual shut-
off valve during any pressure
testing of the gas supply piping system at test pressures
equal to or less
than 1/2 psig (3.5 kPa.).
The appliance
and its individual
shut off valve must be disconnected
from the gas supply piping system
during any pressure
testing of the system
at test pressures
in excess
of 1/2 psig (3.5 kPa.).
When checking
the manifold
gas pressure,
the inlet pressure
to the regulator
should be at least 6" W.C.
(14.9 mb) for natural gas or 11" W.C. (27A
mb) for propane.
Do not attempt
any adjustment
of the pressure
regulator.