Step 5: Gas Requirements
and Hookup
Verify the type of gas being used at the installation
site.
As shipped
from the factory,
units are configured
for
use with natural gas.Make
certain the range matches
the type of gas available
at this location.
For installation
of the appliance
at high altitude, please
consult your local gas company
for their recommen-
dation
of the correct
orifice
sizes
and any
other
necessary
adjustments
that will provide
proper gas
combustion
at specified
altitudes.
CAUTION
When
connecting
unit to propane
gas,
make
certain the propane gas tank is equipped
with its
own high pressure
regulator
in addition
to the
pressure
regulator
supplied
with the appliance.
The pressure
of the gas supplied
to the appli-
ance
regulator
must
not
exceed
14"
(34.9 mb) water column.
NaturaJ
Inlet Connection:
Supply
Pressure:
Manifold
Pressure:
Gas
Requirements:
3/4" N.P.T. external
1/2" N.P.T. internal
(Minimum
3/4" dia. flex line.)
6" to 14" water column.
(14.9 to 34.9 mb)
5" water column
(12.5 mb)
Supply
Pressure:
Manifold
Pressure:
Propane
Gas
Requirements:
Inlet Connection:
3/4" N.P.T. external
1/2" N.P.T. internal
(Minimum
3/4" dia. flex line.)
11" to 14" water column.
(27.4 mb to 34.9 mb)
10" water column
(24.9 mb)
WARNmNG
Gas line must not come in contact
with any components
inside
back
cover
of range.
Run gas
line in
channel
in back of range.
HOOK
UP
A manual
gas shut-off
valve
must be installed
external to the appliance,
in a location accessible
from the front, for the purpose
of shutting
off the
gas supply. The supply line must not interfere with
the back of the unit. Make sure the gas supply is
turned
off at the manual
shut-off
valve
before
connecting
the appliance.
The range is supplied
with its own pressure
regu-
lator that has been permanently
mounted
within
the range body.
Use 3/4" flex line to connect
between
the gas
supply
and the appliance
manifold
pipe, which
exits the upper rear of the appliance.
The appli-
ance manifold
pipe connection
is 3/4" NPT. (See
Photo A.) Use caution to avoid crimping
the 3/4"
flex line when making bends.
The gas supply connections
should be made by a
competent
technician
and in accordance
with
local codes or ordinances.
In the absence
of a
local code, the installation
must conform
to the
National
Fuel Gas Code ANSI Z223.1iNFPA54-
current
issue.
Always use pipe dope or Teflon _)tape on the pipe
threads,
and be careful
not to apply excessive
pressure
when tightening
the fittings.
Leak testing
of the appliance
shall be in accor-
dance with the following
instructions.
• Turn on gas and check supply line connections
for leaks using a soap and water solution.
Bubbles
forming
indicate
a gas leak. Repair all
leaks immediately
after finding
them.
• Do not use a flame
of any kind to check
for
gas _eaks.
Photo
A
Channel
forgas
line
Use 3/4" flex line to connect
between
the
gas
supply
and
the
appliance
manifold
pipe, which
exits the upper
rear of the appliance.
13

Advertisement

loading

This manual is also suitable for:

Pd304Pd48Pd36Lb36rPd484ggePd364gl ... Show all