Step 5: Gas Requirements And Hookup - Thermador Professional PRO-GRAND PRD30 Installation Manual

Dual fuel ranges
Hide thumbs Also See for Professional PRO-GRAND PRD30:
Table of Contents

Advertisement

Available languages

Available languages

| 2-4/2" |
from edge of range
Wall Line
-_
a n
\ me!
|
!
|
S,
VA
Floor
Left
Cabinet
Right Cabinet
Right
Cabinet
[Esto
Front Edge of | |
(typical -
|
either side)
*
Prepare holes at fastener locations as identified below:
*
For wails, wall studs, or floors composed of solid
wood or metal, drill 1/8" pilot holes.
*
For walls or floors composed of drywall, sheet-rock
or other soft materials,
drill 3/16" holes to a mini-
mum depth of 1-3/4", then tap plastic anchors into
each of the holes using a hammer.
*
For walls or floors composed of concrete or con-
crete block, drill 3/16" holes to a minimum depth of
1-3/4", then tap concrete anchors into each of the
holes using a hammer.
*
For walls or floors having ceramic tile covering, drill
3/16" holes through the tile only, then drill into the
material behind the tile as indicated immediately
above.
+
If the range is moved to a new location, the Anti-Tip
Device must be removed and reinstalled.
Mounting Anti-Tip Bracket
The alternative floor mounted
bracket shall be installed as
follows:
1.
Place bracket on floor in position shown in Figure 7b
(Bracket may be used in either corner of the installation
area).
2.
Secure to floor or wall stud.
3.
Later, when the unit is installed, the adjustable leg will
slide under the bracket.
Figure 7b: Placement of Anti-Tip Bracket (Top View)
Step 5: Gas Requirements and
Hookup
Verify the type of gas being used at the installation site.
The appliance is shipped from the factory for use with
natural gas. It must be converted for use with propane.
A qualified technician or installer must do the
conversion. Make certain the range matches the type of
gas available at this location.
The field conversion kit for this series of dual-fuel ranges is
Thermador Model PLPKIT. Obey all instructions in this kit
for correct conversion of the gas regulator and settings for
the gas valves.
A
CAUTION:
When connecting unit to propane gas, make
certain the propane gas tank is equipped with its
own high pressure regulator in addition to the
pressure regulator supplied with the appliance.
The pressure of the gas supplied to the
appliance regulator must not exceed 14" (34.9
mb) water column.
This appliance has been CSA certified for safe operation
up to an elevation of 10,200 ft. without any modifications.
Exception: For use with propane, the appliance must be
converted per the LP conversion instructions.
English 11

Advertisement

Table of Contents
loading

Table of Contents