Connections (Is-Ipdv And Is-Ipdvf) - Aiphone IS SERIES Installation Manual

Commercial & security ip video intercom system network direct system
Hide thumbs Also See for IS SERIES:
Table of Contents

Advertisement

■ Connections (IS-IPDV and IS-IPDVF)

*2
Electric door strike
φ 0.65-1.2mm
(22-16AWG)
10m (33')
Connect to the electric door strike
according to its specifi cations.
*1: A power supply unit is not needed when using a switch or injector that has a PoE (Power over Ethernet) function. The unit is supplied with power
along with data signal via a LAN cable.
*2: Output specifi cations
Output method
Voltage between
terminals
NOTES:
Do not use the unoccupied terminals and ports for other purposes.
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
For connecting other manufacturer's products, refer to the instruction manuals for those products.
The illustration of the unit's rear panel differs from the actual one. This is for simplifying the connection diagram.
LAN/PoE
φ 0.65-1.2mm
(22-16AWG)
10m (33')
AC transformer
PT
DC
24V
φ 0.65-1.2mm
(22-16AWG)
10m (33')
N/O or N/C dry closure contact
24V AC, 0.5A (resistive load)
24V DC, 0.5A (resistive load)
Minimum overload (AC/DC):
100mV, 0.1mA
Option
Inlet
wires
Terminal cover
CAT5e/6 cable
CAT5e/6
(non-shielded)
100m (330')
10BASE-T/100BASE-TX
φ 0.65-1.2 (22-16AWG)-2C
15m (50')
P
The terminals are inside the terminal
cover. After connecting, route the
wires through the wiring paths, then
close the cover.
Be sure to route the CAT5e/6 cable
and option wires through inlet.
When closing the terminal cover,
close it until it clicks.
Switch (Hub)
Power supply unit *1
(PS-2420/D/UL/S)
P: Polarized