Troubleshooting
Run/Attention/Fault LED States
Run
Attn
(Green)
(Amber)
Off
Off
Off
Off
Off
Flashing
110
Fault
Description
(Red)
State:
On
Boot failed
OS not up and running, PDC has detected a
failure that is preventing boot from occurring.
Action:
1. Check chassis error logs
2. Read console messages for indications of
problems ie. warnings from PDC
This is an invalid indication. Check the server's LEDs
and try again.
Flashing
State:
Off
No code is executing (PDC, OS or Diagnostics)
Non-critical error detected (ie. fan failure, power
supply failure) (Double fault situation)
Action:
Cannot execute PDC. If more than one processor
installed, the problem is most likely a failed
system board. If only one processor installed,
problem could be either the processor or system
board.
Check chassis error logs to determine the source
of non-critical error.