Run
Attn
(Green)
(Amber)
On
Flashing
On
Flashing
Chapter 6
Fault
Description
(Red)
This is an invalid indication. Check the server's LEDs
and try again.
On
State:
Flashing
System running, and
A) unexpected reboot occurred, and
B) a non-critical error has been detected
Action:
A) Check chassis error logs to determine
probable cause of system crash (either HPMC or
HP-UX System Panic)
A) Check GSP console logs for potential error
messages from the OS (ie. Panic messages)
B) Check chassis error logs to determine
probable cause of non-critical error
B) Check Sentinel logs for probable cause of
non-critical error
Troubleshooting
Run/Attention/Fault LED States