Table 4-2
Class: SMX_SAArraySystem (CIM_ComputerSystem)
Property name
ElementName
OperationalStatus[0]
StatusDescriptions[0]
EnabledDefault
EnabledState
RequestedState
CreationClassName
Name
NameFormat
Property implementation
Controller/Storage System name and location
Examples:
Smart Array in Slot=3, for internal
Smart Array Embedded Controller=7 for embedded
controller where 7 is the internal identifier for the
embedded controller
CIM_ManagedSystemElement
Overall status of the Array System and attached
devices. This is calculated per the algorithm desciribed
in the HP Smart Array Profile.
0 (Unknown)
2 (OK)
3 (Degraded)
6 (Error)
More info for OperationalStatus result. This provides a
short decription to identify who is contributing to non-
OK status.
Examples:
Controller Failure
Logical Drive Failure
Storage Enclosure Failure
Controller Non-Failure Problem
Physical Drive Non-Failure Problem
Logical Drive Non-Failure Problem
Storage Enclosure Non-Failure Problem
Array is operating properly
Array status is unknown
CIM_LogicalElement
CIM_EnabledLogicalElement
2 (Enabled)
5 (Not Applicable)
12 (Not Applicable)
CIM_System
SMX_SAArraySystem
Controller Serial Number
Note: EMBEDDED-<id> is reported if there is no Serial
Number for device is local i.e embedded on
motherboard.
PCISLOT-<Slot number> is reported if there is no Serial
Number for device is local i.e.PCI occupies slot.
Other
CIM_ComputerSystem
Smart Array 47