Smx_Sasstorageenclosureprocessor - HP ProLiant BL280c - G6 Server Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

Table 6-26
Class: SMX_SASStorageEnclosure (HP_StorageEnclosure)
Property name
PartNumber
SerialNumber
Tag
Version
RemovalConditions
Location

SMX_SASStorageEnclosureProcessor

6-1-27
SMX_SASStorageEnclosureProcessor represents the management processor within a Storage
Enclosure. This instance contains the operational status for all managed components in the enclosure if
applicable.
Table 6-27
Class: SMX_SASStorageEnclosureProcessor (CIM_ComputerSystem)
Property name
ElementName
OperationalStatus[0,1, 2, 3 ]
Property implementation
N/A—Not available in this implementation
Enclosure Serial Number
N/A is reported if there is no serial number (for
example, internal enclosures).
Opaque key
N/A—Not available in this implementation
CIM_PhysicalPackage
2 (Not Applicable)
CIM_PhysicalFrame
CIM_Chassis
HP_StorageEnclosure
See HP Storage Enclosure Profile
SMX_SASStorageEnclosure
Property implementation
CIM_ManagedElement
Port: <m> Box: <n>, where <m> is the port and <n> is
the box number
CIM_ManagedSystemElement
Operational status for enclosure and associated power
supplies, fans, and sensors.
The use of OperationalStatus is described in the HP
Storage Enclosure Profile. Index values are populated
as follows:
Index[0]—Enclosure status:
0 (Unknown)
2 (OK)
3 (Degraded)
6 (Error)
Index[1]—Fan status (See Profile)
Index[2]—Power Supply status (See Profile)
Index[3]—Temp Sensor Status (See Profile)
SMX_SAS HBA Provider 178

Advertisement

Table of Contents
loading

Table of Contents