Logical Drive Status Ok - HP ProLiant BL280c - G6 Server Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

Table 6-76
HP_DeviceIndication: Drive status PREDICTIVE FAILURE
Property name
SystemModel
SystemGUID
VariableNames
VariableTypes
VariableValues
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
SystemVirtualSerialNumber
SystemVirtualUUID
HWFirmwareVersion
HWLogicalLocation
HWManufacturer
HWSerialNumber
DeviceModel

Logical Drive status OK

6-2-7
Table 6-77
HP_DeviceIndication: Logical Drive status OK
Property name
Property implementation
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
FailureDescription
1 (String)
Short Description of failure
In some cases, the property VariableValues can have
N/A or "" values.
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
Disk firmware version string
Disk Location string
For example, Bay 3
Disk Manufacturer string
Disk Serial Number
HP_DeviceIndication
Disk Model string
Property implementation
SMX_SAS HBA Provider 202

Advertisement

Table of Contents
loading

Table of Contents