Enclosure Power Supply Status Changed To Redundant Degraded - HP ProLiant BL280c - G6 Server Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

Table 6-81
HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name
SystemVirtualUUID
HWLogicalLocation
HWSerialNumber
DeviceModel
Enclosure Power Supply Status changed to Redundant
6-2-12
Degraded
Table 6-82
HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Property implementation
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
Enclosure Location string
For example, Port 1I Box 1
Enclosure Serial Number
HP_DeviceIndication
Enclosure Model string
Property implementation
CIM_Indication
GUID string generated at the time of indication
3 (Warning)
Time of indication
CIM_AlertIndication
A Storage Enclosure Power Supply status has changed
to Degraded Redundancy.
WBEM Path of SMX_SASStorageEnclosureProcessor
2 (CIMObjectPath)
5 (Device Alert)
303
Time of the event or time of the indication if event time
unknown
HP SAS
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
SMX_SAS HBA Provider 212

Advertisement

Table of Contents
loading

Table of Contents