Interpreting Messages; Example; About Security Audit Logging; Syslog Message Components - Enterasys C5G124-24 Configuration Manual

Fixed switch platforms
Hide thumbs Also See for C5G124-24:
Table of Contents

Advertisement

Interpreting Messages

For more information on how to configure these basic settings, refer to
Precedence" on page 14-8, and the

Interpreting Messages

Every system message generated by the Enterasys switch platforms follows the same basic format:
<facility/severity> time stamp address application [unit] message text

Example

This example shows Syslog informational messages, displayed with the show logging buffer
command. It indicates that messages were generated by facility code 16 (local4) at severity level 5
from the CLI application on IP address 10.42.71.13.
Switch1(rw)->show logging buffer
<165>Sep
<165>Sep
(telnet)
Table 14-2
Table 14-2 Syslog Message Components
Component
Facility/Severity
Time stamp
Address
Application
Unit
Message text

About Security Audit Logging

Security audit logging provides a mechanism to generate a separate and secure log file, in
addition to the previously existing unsecured log file ("current.log").
The secure permanent log file, named "secure.log," records security related events occurring on
the switch. The secure log file contains 1000 256-byte log entries and is managed as a circular list.
Up to 10 files are allowed in the secure directory, with a total size of 512 KB.
The "secure.log" file is stored in the secure/logs directory, which is only visible to and accessible
by super user accounts. Super-users can create, edit, and delete files in the secure directory, and
can copy files to and from the secure directory.
14-6 Configuring Syslog
4 07:43:09 10.42.71.13 CLI[5]User:rw logged in from 10.2.1.122 (telnet)
4 07:43:24 10.42.71.13 CLI[5]User: debug failed login from 10.4.1.100
describes the components of these messages.
Description
Combined code indicating the facility generating
the message and the severity level used to
determine message priority. Facility codes 16 -
23 are Syslog designations for local0 - local7,
the Enterasys supported designations for local
use. For a complete list of facility codes, refer to
RFC 3164.
Month, date, and time the Syslog message
appeared.
IP address of the client originating the Syslog
message.
Client process generating the Syslog message.
Location of the device generating the Syslog
message.
Brief description of error condition.
"Configuration
Examples" on page 14-12.
"Syslog Command
Example Code
<165> = Numerical code
indicating a message from
facility local4 at severity
5.
Sep
4 07:43:09
10.42.71.13
CLI
[5] = unit 5 in stack
User: debug failed login
from 10.4.1.100 (telnet)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents