Enterasys C5G124-24 Configuration Manual page 38

Fixed switch platforms
Hide thumbs Also See for C5G124-24:
Table of Contents

Advertisement

Downloading Firmware via the Serial Port
Header Version..................0x0100
Image Type......................0x82
Image Offset....................0x004d
Image length....................0x006053b3
Ident Strings Length............0x0028
Ident Strings...................
<platform specific>
Image Version Length............0x8
Image Version Bytes.............0x30 0x2e 0x35 0x2e 0x30 0x2e 0x34 (x.xx.xx)
The following secondary header is in the image:
CRC............................................0xe6aa (59050)
Target Device..................................0x00a08245
Size...........................................0x58f210 (5829136)
Number of Components...........................2
Operational Code Size..........................0x51d5b8 (5363128)
Operational Code Offset........................0x0 (0)
Operational Code CRC...........................0x1FC1
Boot Code Version..............................29
Boot Code Size.................................0x71a08 (465416)
Boot Code Offset...............................0x51d5b8 (5363128)
Boot Code CRC..................................0x4CCD
VPD - rel 6 ver 61 maint_lvl xx
Operational code update completed successfully.
Verifying Operational Code CRC.....
12. Press ENTER so the switch will complete the file transfer operation, displaying a fresh
prompt.
[Boot Menu] 2
13. Type 2 to display the baud rate selection screen again.
14. Type 4 to set the switch baud rate to 9600. The following message displays:
Setting baud rate to 9600, you must change your terminal baud rate.
15. In your terminal emulation program, set the terminal baud rate to 9600.
16. Press ENTER so the switch will complete the baud rate change and display a fresh prompt.
[Boot Menu] 1
17. Type 1 to start the new operational code. A message similar to the following displays:
Operational Code Date: Tue Jun 29 08:34:05 2011
Uncompressing.....
18. After the switch comes back up, log in and confirm that the new image has been detected and
is now running. You can use either the "show boot system" command or the "dir" command.
C5(rw)->show boot system
Current system image to boot: c5-series_06.61.xx
C5(rw)->
1-12 Setting Up a Switch for the First Time
Timestamp - Wed Jul 27 12:24:04 2011
File - c5-series_06.61.xx
HyperTerminal: File > Properties > Configure > Bits per Second > Apply > OK > OK
TeraTerm: Setup > Serial port > Baud rate > OK
CRC is OK.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents