Lamp Replacement - Sanyo PLC-WL2503 Owner's Manual

Sanyo - plc-wl2503 lcd projector - 720p - 16:10
Hide thumbs Also See for PLC-WL2503:
Table of Contents

Advertisement

When the projection lamp of the projector reaches its end
of life, the Lamp replacement icon appears on the screen
and LAMP REPLACE indicator lights yellow. Replace the
lamp with a new one promptly. The timing when the LAMP
REPLACE indicator should light is depending on the lamp
mode.
WARNING:
TURN OFF THE UV LAMP BEFORE
OPENING THE LAMP COVER
CAUTION
When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp may be
broken. If replacing the lamp of a projector which has been installed on the ceiling, you should always
assume that the lamp is broken, and you should stand to the side of the lamp cover, not underneath it.
Remove the lamp cover gently. Small pieces of glass may fall out when the lamp cover is opened. If pieces
of glass get into your eyes or mouth, seek medical advice immediately.
CAUTION
Allow a projector to cool for at least 45 minutes
before you open the Lamp Cover. The inside of
the projector can become very hot.
Follow these steps to replace the lamp.
1
Turn off the projector and unplug the AC power cord.
Let the projector cool for at least 45 minutes.
2
Loosen the screw and open the lamp cover.
3
Loosen the three (3) screws that secure the lamp. Lift
the lamp out of the projector by using the handle.
4
Replace the lamp with a new one and secure the three
(3) screws. Make sure that the lamp is set properly.
Close the lamp cover and secure the screw.
5
Connect the AC power cord to the projector and turn
on the projector.
6
Reset the lamp counter .
See "Resetting the Lamp Counter" on the next page.
ORDER REPLACEMENT LAMP
Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following
information to the dealer.
Model No . of your projector
Replacement Lamp Type No .

Lamp Replacement

For continued safety, replace with a lamp of the
same type. Do not drop a lamp or touch a glass
bulb! The glass can shatter and may cause injury.
: PLC-WL2503
: POA-LMP141
(Service Parts No. 610 349 0847)
Maintenance and Cleaning
Top Panel
This indicator turns yellow
when the projection lamp
reaches the end of its life.
Lamp replacement icon
Note:
The Lamp replacement icon (Fig.1) will not appear
when the Display function is set to Off (p.46), during
Freeze(p.25), or No show (p.26).
CAUTION
Lamp Cover
Screw
Handle
Screws
Lamp
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wl2503 - 2500 lumens