Regional Tab
VMWI Refresh Intvl
Interdigit Long Timer
Interdigit Short Timer
CPC Delay
CPC Duration

Vertical Service Activation Codes

Vertical Service Activation Codes are automatically appended to the dial-plan. There is
need to include them in dial-plan, although
Field
Call Return Code
Call Redial Code
Blind Transfer Code
Linksys IP Phone Administrator Guide
5-24
Interval between VMWI refresh to the CPE.
The default is 0.5.
Long timeout between entering digits when dialing. The interdigit timer values are used
as defaults when dialing. The Interdigit_Long_Timer is used after any one digit, if all
valid matching sequences in the dial plan are incomplete as dialed. Range: 0–64 seconds.
The default is 10.
Short timeout between entering digits when dialing. The Interdigit_Short_Timer is used
after any one digit, if at least one matching sequence is complete as dialed, but more
dialed digits would match other as yet incomplete sequences. Range: 0–64 seconds.
The default is 3.
Delay in seconds after caller hangs up when the Linksys IP phone starts removing the
tip-and-ring voltage to the attached equipment of the called party. Range: 0–255 seconds.
Linksys IP phone has had polarity reversal feature since release 1.0 which can be applied
to both the caller and the callee end. This feature is generally used for answer supervision
on the caller side to signal to the attached equipment when the call has been connected
(remote end has answered) or disconnected (remote end has hung up). This feature should
be disabled for the called party (in other words, by using the same polarity for connected
and idle state) and the CPC feature should be used instead.
Without CPC enabled, reorder tone will is played after a configurable delay.
If CPC is enabled, dial tone will be played when tip-to-ring voltage is restored
Resolution is 1 second.
The default is 2.
Duration in seconds for which the tip-to-ring voltage is removed after the caller hangs up.
After that, tip-to-ring voltage is restored and dial tone applies if the attached equipment
is still off-hook. CPC is disabled if this value is set to 0. Range: 0 to 1.000 second.
Resolution is 0.001 second.
The default is 0 (CPC disabled).
Description
This code calls the last caller.
The default is *69.
Redials the last number called. (Not in PAP2T)
The default is *07.
Begins a blind transfer of the current call to the extension specified after the activation
code.
The default is *98.
Chapter 5
harm is done if they are included.
no
Linksys ATA Field Reference
no
Document Version 3.2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents