Using Legacy Commands For Snmpv1 - HP AE370A - Brocade 4Gb SAN Switch 4/12 Administrator's Manual

Hp storageworks fabric os 5.2.x administrator guide (5697-0014, may 2009)
Hide thumbs Also See for AE370A - Brocade 4Gb SAN Switch 4/12:
Table of Contents

Advertisement

Using legacy commands for SNMPv1

You should use the snmpConfig command to configure the SNMPv1 agent and traps (refer to
snmpConfig
command" on page 94). However, if necessary for backward compatibility, you can choose
to use legacy commands.
Sample SNMP agent configuration information
switch:admin> agtcfgshow
Current SNMP Agent Configuration
Customizable MIB-II system variables:
SNMPv1 community and trap recipient configuration:
Community 1: Secret C0de (rw)
Trap recipient: 192.168.1.51
Trap recipient Severity level: 4
Community 2: OrigEquipMfr (rw)
Trap recipient: 192.168.1.26
Trap recipient Severity level: 0
Community 3: private (rw)
No trap recipient configured yet
Community 4: public (ro)
No trap recipient configured yet
Community 5: common (ro)
No trap recipient configured yet
Community 6: FibreChannel (ro)
No trap recipient configured yet
SNMP access list configuration:
Entry 0:
Entry 1:
Entry 2:
Entry 3:
Entry 4:
Entry 5:
sysDescr = FC Switch
sysLocation = End User Premise
sysContact = Field Support.
authTraps = 1 (ON)
Access host subnet area 192.168.64.0 (rw)]
No access host configured yet
No access host configured yet
No access host configured yet
No access host configured yet
No access host configured yet
Fabric OS 5.2.x administrator guide
"Using the
97

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents