Port Mirroring - HP AE370A - Brocade 4Gb SAN Switch 4/12 Administrator's Manual

Hp storageworks fabric os 5.2.x administrator guide (5697-0014, may 2009)
Hide thumbs Also See for AE370A - Brocade 4Gb SAN Switch 4/12:
Table of Contents

Advertisement

VE_Port—Functions somewhat like an E_Port, but terminates at the switch and does not propagate
fabric services or routing topology information from one edge fabric to another.
VEX_Port—A type of VE_Port that connects a Fibre Channel router to an edge fabric. From the point of
view of a switch in an edge fabric, an VEX_Port appears as a normal VE_Port. It follows the same Fibre
Channel protocol as other VE_Ports. However, the router terminates VEX_Ports rather than allowing
different fabrics to merge as would happen on a switch with regular VE_Ports.
The FCP auto discovery process enables private storage devices that accept PRLI to communicate in a
fabric.
If device probing is enabled, the embedded port PLOGIs and attempts a PRLI into the device to retrieve
information to enter into the Name Server. This enables private devices that do not FLOGI but accept PRLI
to be entered in the Name Server and receive full fabric citizenship. Private devices that accept PRLI
represent a majority of storage targets. Private hosts require the QuickLoop feature, which is not available
in Fabric OS v4.0.0 or later.
A fabric-capable device will implicitly register information with Name Server during a FLOGI. These
devices will typically register information with the Name Server before querying for a device list. The
embedded port will still PLOGI and attempt PRLI with these devices.
You can view the Name Server table in Web Tools by clicking Name Server in the fabric toolbar. Refer
to the Web Tools Administrator's Guide for more information.

Port mirroring

Port mirroring lets you configure a switch port as an analyzer port to mirror a specific source port and
destination port traffic passing though any switch port. This is a useful way to troubleshoot without bringing
down the host and destination links to insert an inline analyzer.
Port mirroring captures traffic between two devices. It mirrors only the frames containing the SID/DID to the
mirror port. Because of the way it handles mirroring, a single mirror port can mirror multiple mirror
connections. This also means that the port cannot exceed the maximum bandwidth of the mirror port.
Attempts to mirror more traffic than available bandwidth result in the port mirror throttling the SID/DID
traffic so that traffic does not exceed the maximum available bandwidth.
Port mirroring is supported between VE_ports (VE_Port to VE_Port) with FCIP and no routing, and over VEx
_Ports and Ex_Ports. The mirror port can be any port located on the same switch as the source identifier
(SID).
Use port mirroring to detect missing frames, which might occur with zoning issues or hold timeouts, capture
protocol errors, and capture ULP traffic (SCSI/FICON). This feature cannot be used on embedded switch
traffic.
Port mirroring is only available using the FOS 5.2.x CLI and is not available through Web Tools. For a
complete list of port mirroring commands, see the Fabric OS Command Reference Manual.
In order to ensure proper failover in HA configurations, both the active and the standby control processors
(CP) must have firmware version 5.2 installed and running. If the OS on the standby CP does not support
mirroring, failing over the standby CP could cause the HA failover to fail.
Fabric OS 5.2.x administrator guide 301

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents