How To Set The Switch Status Policy Threshold Values - HP AE370A - Brocade 4Gb SAN Switch 4/12 Administrator's Manual

Hp storageworks fabric os 5.2.x administrator guide (5697-0014, may 2009)
Hide thumbs Also See for AE370A - Brocade 4Gb SAN Switch 4/12:
Table of Contents

Advertisement

parameter is set to 3, the status of the switch will change if 3 ports fail. Only one policy parameter needs
to pass the MARGINAL or DOWN threshold to change the overall status of the switch.
For more information about setting policy parameters, refer to the Fabric Watch Administrator's Guide.

How to set the switch status policy threshold values

1.
Connect to the switch and log in as admin.
2.
Enter the switchStatusPolicySet command at the command line.
The current switch status policy parameter values are displayed. You are prompted to enter values for
each DOWN and MARGINAL threshold parameter:
NOTE:
By setting the DOWN and MARGINAL value for a parameter to 0,0 that parameter is no longer
used in setting the overall status for the switch.
3.
Verify the threshold settings you have configured for each parameter.
Enter the switchStatusPolicyShow command to view your current switch status policy
configuration:
HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, SAN Switch
4/32, 4/64 SAN Switch, and 400 MP Router: The following example shows the command as
executed on a SAN Switch 2/32 switch. The output is similar on SAN Switch 2/8V, SAN Switch 2/16V,
SAN Switch 4/32, 4/64 SAN Switch, and 400 MP Router models:
:
switch:admin> switchstatuspolicyset
To change the overall switch status policy parameters
The current overall switch status policy parameters:
----------------------------------
PowerSupplies
Temperatures
MarginalPorts
FaultyPorts
MissingSFPs
Note that the value, 0, for a parameter, means that it is
NOT used in the calculation.
** In addition, if the range of settable values in the prompt is (0..0),
** the policy parameter is NOT applicable to the switch.
** Simply hit the Return key.
Bad PowerSupplies contributing to DOWN status: (0..2) [2] 0
Bad PowerSupplies contributing to MARGINAL status: (0..2) [1] 0
Bad Temperatures contributing to DOWN status: (0..6) [2] 0
Bad Temperatures contributing to MARGINAL status: (0..6) [1] 0
Bad Fans contributing to DOWN status: (0..3) [2] 0
Bad Fans contributing to MARGINAL status: (0..3) [1] 0
Out of range Flash contributing to DOWN status: (0..1) [0] 0
Out of range Flash contributing to MARGINAL status: (0..1) [1] 0
MarginalPorts contributing to DOWN status: (0..32) [2] 0
MarginalPorts contributing to MARGINAL status: (0..32) [1] 0
FaultyPorts contributing to DOWN status: (0..32) [2] 0
FaultyPorts contributing to MARGINAL status: (0..32) [1] 0
MissingSFPs contributing to DOWN status: (0..32) [0] 0
MissingSFPs contributing to MARGINAL status: (0..32) [0] 0
Policy parameter set has been changed
rint12:admin>
SAN Director 2/128 and 4/256 SAN Director: Command output includes parameters related to
CP blades.
50
Performing basic configuration tasks
Down
Marginal
2
1
2
1
Fans
2
1
Flash
0
1
2
1
2
1
0
0