Monitoring filter-based performance

Filter-based performance monitoring counts the number of times a frame with a particular pattern is
transmitted by a port. Filter-based monitoring is achieved by configuring a filter for a particular purpose.
The filter can be a standard filter (for example, a SCSI read command filter that counts the number of SCSI
read commands that have been transmitted by the port) or a user-defined filter customized for your
particular use.
For 4/16 SAN Switch and 4/8 SAN Switch, SAN Switch 2/16V, SAN Switch 2/32, and SAN Director
2/128 models, the maximum number of filters is 8 per port, in any combination of standard filters and
user-defined filters.
For the SAN Switch 4/32, 4/64 SAN Switch, 400 MP Router and 4/256 SAN Director models, the
maximum number of filters is 12 per port, in any combination of standard filters and user-defined filters.
The actual number of filters that can be configured on a port depends on the complexity of the filters. For
trunked ports, the filter is configured on the trunk master.
For the 4/256 SAN Director, the maximum number of filters is 12 per port, in any combination of standard
filters and user-defined filters, except for the FC4-48 port blade. For the FC4-48 port blade:
Ports 0 through 15 have a maximum of 12 filter monitors per port.
Ports 16 through 31 have a maximum of 6 filter monitors per port.
Ports 32 through 47 do not have filter monitors.
For the FC4- 1 6IP port blade, the maximum number of filters is 12 per port and 15 offsets per port. At the
time of this document's release, HP does not support the FC4- 1 6IP iSCSI blade. Consult
http://www.hp.com
The actual number of filters that can be configured on a port depends on the complexity of the filters. For
trunked ports, the filter is configured on the trunk master.
You can monitor filter-based performance using the perfMonitorShow command, as described in
"Displaying monitor
perfMonitorClear command, as described in

Adding standard filter-based monitors

Table 65
lists the commands for adding standard filter-based monitors to a port.
Table 65
Commands to add filter-based monitors
Telnet command
perfAddReadMonitor
perfAddWriteMonitor
perfAddRwMonitor
perfAddScsiMonitor
perfAddIpMonitor
You cannot add identical filter monitors to the same port. Two filter monitors are considered to be identical
when they have the same:
Filter monitor type
Owner (telnet, Web Tools, etc.)
Alias
for the latest, updated information.
counters" on page 321. You can clear filter-based counters using the
Description
Count the number of SCSI Read commands
Count the number of SCSI Write commands
Count the number of SCSI Read and Write commands
Count the number of SCSI traffic frames
Count the number of IP traffic frames
"Clearing monitor
counters" on page 323.