How to display the status of the track changes feature

1.
Connect to the switch and log in as admin.
2.
Enter the trackChangesShow command.
The status of the track changes feature is displayed as either on or off. The display includes whether the
track changes feature is configured to send SNMP traps:
switch:admin> trackchangesshow
Track changes status: ON
Track changes generate SNMP-TRAP: NO
switch:admin>

How to view the switch status policy threshold values

1.
Connect to the switch and log in as admin.
2.
Enter the switchStatusPolicyShow command at the command line.
Whenever there is a switch change, an error message is logged and an SNMP connUnitStatusChange
trap is sent.
HP StorageWorks 4/16 SAN Switch and 4/8 SAN Switch, SAN Switch 2/8V, SAN
Switch 2/16V, SAN Switch 2/32, SAN Switch 4/32, 4/64 SAN Switch, and 400 MP
Router:
The output is similar to the following:
switch:admin> switchstatuspolicyshow
The current overall switch status policy parameters:
----------------------------------
PowerSupplies
Temperatures
MarginalPorts
FaultyPorts
MissingSFPs
switch:admin>
HP StorageWorks SAN Director 2/128 and 4/256 SAN Director:
The output is similar to the following:
switch:admin> switchstatuspolicyshow
The current overall switch status policy parameters:
----------------------------------
PowerSupplies
Temperatures
MarginalPorts
FaultyPorts
MissingSFPs
switch:admin>
The policy parameter determines the number of failed or inoperable units for each contributor that will
trigger a status change in the switch.
Each parameter can be adjusted so that a specific threshold must be reached before that parameter
changes the overall status of a switch to MARGINAL or DOWN. For example, if the FaultyPorts DOWN
Down
Marginal
2
1
2
1
Fans
2
1
Flash
0
1
5
2
2
1
2
1
Down
Marginal
3
0
2
1
Fans
2
1
WWN
0
1
CP
0
1
Blade
0
1
Flash
0
1
2
1
2
1
0
0
Fabric OS 5.2.x administrator guide