IBM 88643RU - System x3850 - 8864 Service Manual page 140

Problem determination and service guide
Hide thumbs Also See for 88643RU - System x3850 - 8864:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8864," on page 23 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a
trained service technician.
Error code
Description
166-400-000
ISMP Self Test Result failed tests: xxx
where xxx=flash, ROM, or RAM.
166-400-100
DMC Self Test Result failed tests: xxx where
xxx=flash, ROM, or RAM.
180-197-000
SCSI ASPI driver not installed.
180-361-003
Failed fan LED test.
180-xxx-000
Diagnostics LED failure.
124
IBM System x3850 Type 8864: Problem Determination and Service Guide
Action
1. Disconnect all server and option power cords
from the server, wait 30 seconds, reconnect the
power cords, and retry.
2. Update the BMC firmware (see "Updating the
firmware" on page 13).
3. Reseat the I/O board.
4. Replace the I/O board.
1. Disconnect all server and option power cords
from the server, wait 30 seconds, reconnect the
power cords, and retry.
2. Update the BIOS code, BMC, service processor,
and diagnostics firmware (see "Updating the
firmware" on page 13).
1. Remove the RAID adapter, if one is installed, and
run the test again.
2. Reseat the following components:
a. SAS hard disk drive backplane cables
b. I/O board
c. Microprocessor tray
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. SAS hard disk drive backplane
b. I/O board
c. (Trained service technician only)
Microprocessor tray
1. Reseat the following components:
a. Fan
b. I/O board
2. Replace the components listed above one at a
time, in the order listed above, restarting the
server each time.
Run the diagnostic LED test for the failing LED.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x38508864

Table of Contents