v When you run the diagnostics programs, a single problem might cause several
v Before running the diagnostics programs, you must determine whether the failing
v If the server is suspended and a POST error code is displayed, see "Error logs"
v For information about power-supply problems, see "Solving power problems" on
v For intermittent problems, check the error log; see "Error logs" on page 70 and

Performing the checkout procedure

To perform the checkout procedure, complete the following steps:
keyboard, mouse (pointing device), serial ports, and hard disk drives. You can
also use them to test some external devices. If you are not sure whether a
problem is caused by the hardware or by the software, you can use the
diagnostics programs to confirm that the hardware is working correctly.
error messages. If you receive several error messages, correct the cause of the
first error message. The other error messages might not occur the next time you
run the diagnostics programs.
server is part of a shared hard disk drive cluster (two or more servers sharing
external storage devices). If it is part of a cluster, you can run all diagnostics
programs except the ones that test the storage unit (that is, a hard disk drive in
the storage unit) or the storage adapter that is attached to the storage unit. The
failing server might be part of a cluster if any of the following conditions is true:
– You have identified the failing server as part of a cluster (two or more servers
sharing external storage devices).
– One or more external storage units are attached to the failing server and at
least one of the attached storage units is also attached to another server or
unidentifiable device.
– One or more servers are located near the failing server.
Important: If the server is part of a shared hard disk drive cluster, run one test
at a time. Do not run any suite of tests, such as "quick" or "normal" tests,
because this might enable the hard disk drive diagnostic tests.
on page 70. If the server is suspended and no error message is displayed, see
"Problem isolation tables" on page 88 and "Solving undetermined problems" on
page 156.
page 155 and "Power-supply LEDs" on page 108.
"Diagnostic programs, messages, and error codes" on page 110.
001
IS THE SERVER PART OF A CLUSTER?
002
No. Go to step 004 .
003
Yes. Schedule maintenance. Shut down all failing systems that are
related to the cluster. Go to step 004 .
004
v Check the power supply LEDs, see "Power-supply LEDs" on
page 108.
v Turn off the server and all external devices.
v Check all internal and external devices for compatibility at
http://www.ibm.com/servers/eserver/serverproven/compat/us/.
v Check all cables and power cords.
v Set all display controls to the middle positions.
v Turn on all external devices.
v Turn on the server.
87