HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual page 231

Hp storageworks fabric os 6.2 administrator guide (5697-0016, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

5.
Exit the session.
6.
Update the firmware on the standby CP:
a. Connect to the enterprise-class platform and log in as admin to the standby CP.
b. Enter the firmwareDownload -s command and respond to the prompts.
At this point, the firmware should download to the standby CP only. When it has completed the
download to that CP, reboot it. The current enterprise-class platform session will be disconnected.
7.
Fail over to the standby CP.
a. Connect to the enterprise-class platform on the active CP.
b. Enter the haShow command to verify that HA synchronization is complete. It will take a minute or
two for the standby CP to reboot and synchronize with the active CP.
CAUTION:
If you are downgrading from Fabric OS 6.2.0 to 6.1.0, your CPs will not gain synchronization
and this will be a disruptive firmware download. See
synchronization states.
c. Enter the firmwareShow command to confirm that the primary partition of the standby CP
contains the new firmware.
d. Enter the haFailover command. The active CP will reboot and the current enterprise-class
platform session will be disconnected.
If an AP blade is present: At the point of the failover an autoleveling process is activated. See,
"Enterprise-class platform firmware download process
autoleveling.
8.
Verify the failover:
a. Connect to the enterprise-class platform on the active CP, which is the former standby CP.
b. Enter the haShow command to verify that the HA synchronization is complete. It will take a minute
or two for the standby CP, which is the old active CP, to reboot and synchronize with the active CP.
NOTE:
If the CPs fail to synchronize, you can still proceed because the version being tested is
already present on the active CP, and subsequent steps will ensure that the standby CP is updated to
the same version as the active CP.
c. Confirm the evaluation version of firmware is now running on the active CP by entering the
firmwareShow command.
9.
Update firmware on the standby CP:
a. Connect to the enterprise-class platform on the standby CP, which is the old active CP.
b. Enter the firmwareDownload -s command and respond to the prompts.
At this point the firmware should download to the standby CP only and reboot it. The current
enterprise-class platform session will be disconnected.
c. Wait one minute for the standby CP to reboot, and then connect to the enterprise-class platform and
log in as admin.
d. Enter the firmwareShow command to confirm that both primary partitions now have the test drive
firmware in place.
You are now ready to evaluate the new version of firmware.
IMPORTANT:
Stop! If you want to restore the firmware, stop here and skip ahead to
otherwise, continue to
download.
Table 56
step 10
to commit the firmware on both CPs, which completes the firmware
on page 215 for more information on
overview" on page 220 for details about
Fabric OS 6.2 administrator guide 229
step
12;