HP 316095-B21 - StorageWorks Edge Switch 2/24 Installation Manual page 105

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 installation guide (aa-rtdwc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Note:
Preferred Domain ID will change to the current active domain ID if the IDs are
different.
Edge Switch 2/24 Installation Guide
b. Choose Enabled or Disabled from the Insistent Domain drop-down list.
The default state is disabled. This option is not supported unless the
SANtegrity feature is installed.
If insistent domain is enabled, the domain ID configured in the Preferred
Domain ID field will become the active domain identification when the
fabric initializes.
If you enable Insistent Domain while the switch or director is online, the
c. Choose Enabled or Disabled from the Rerouting Delay drop-down list.
The default state is enabled.
If rerouting delay is enabled, traffic is delayed through a fabric by the
specified E_D_TOV time. This delay ensures Fibre Channel frames are
delivered to their destination in order, even if a change to the fabric
topology creates a new (shorter) transmission path.
d. Choose Enabled or Disabled from the Domain RSCNs drop-down list.
The default state is disabled.
Domain register for state change notifications (domain RSCNs) are sent
between end devices in a fabric to provide additional connection
information to host bus adapters (HBAs) and storage devices. As an
example, this information might be that a logical path has been broken
because of a physical event, such as a fiber optic cable being disconnected
from a port. Consult with your HBA and storage device vendor to
determine if enabling Domain RSCNs will cause problems with your
HBA or storage products.
e. Choose Enabled or Disabled from the Suppress RSCNs on Zone set
activations drop-down list. The default state is disabled.
When the parameter is enabled, attached devices do not receive
notification following any change to the fabric's active zone set.
When the parameter is disabled, attached devices (registered through the
fabric format domain register) do receive notification following any
change to the fabric's active zone set.
Using the Embedded Web Server