IBM QS22 - BladeCenter - 0793 Service Manual page 99

Problem determination and service guide
Hide thumbs Also See for QS22 - BladeCenter - 0793:
Table of Contents

Advertisement

Table 12. DIMM boot errors (continued)
Code
Message
No local memory on CPU1
No local memory on CPU2
Slots 1 and 2 should both have
DIMMs plugged
Slots 5 and 6 should both have
DIMMs plugged
Slots [3,7] and [4,8] should have
both DIMMs plugged
E1140
Slots x and y are plugged with
different DIMM types. Disabling
slots.
E1150
DIMMs in slots x and y have
different amount of ranks. Disabling
slots a and b
E1160
DIMMs on CPUx have different
types on channel 1 and 2.
Disabling slots a and b.
W1170
DIMMs on CPux have different
speed bins on channel 1 and 2.
W1180
DIMMs on CPux have different
rank count on channel 1 and 2.
Truncating slots a and b.
Description
No local memory on IBM
PowerXCell 8i processor 1. There
should be DIMMs on IBM
PowerXCell 8i processor 1, but
this is not the case.
No local memory on IBM
PowerXCell 8i processor 2. There
should be DIMMs on IBM
PowerXCell 8i processor 2, but
this is not the case.
Either slot 1 or slot 2 has no
DIMMs plugged, but this should
not be the case.
Either slot 5 or slot 6 has no
DIMMs plugged, but this should
not be the case.
Slots 3,4,7,8 are not completely
plugged.
Slots 1,2,5,6 are plugged,
additional slots are plugged, but
not all of 3,4,7,8.
The type or the speed bin of the
two DIMMs on a given channel
differs.
DIMM rank count on channel
differs.
The number of ranks of the two
DIMMs on a given channel differs.
DIMM types across channels
differ.
The type or speed bin of the
DIMMs on CH0 is different than
the type of the DIMMs on CH1.
DIMM speed bins across channels
differs.
Speed bins on Chx are greater
than those on CHy
DIMM rank count across channels
differs
Action
Replace the DIMM with a
supported DIMM.
See Chapter 3, "Parts listing," on
page 27 for details of supported
DIMMs.
Replace the DIMMs with ones of
the same type.
See Chapter 3, "Parts listing," on
page 27 for details of supported
DIMMs.
Replace the DIMMs with ones of
the same type.
See Chapter 3, "Parts listing," on
page 27 for details of supported
DIMMs.
Replace the DIMMs with ones of
the same type.
See Chapter 3, "Parts listing," on
page 27 for details of supported
DIMMs.
Replace the DIMMs with ones of
the same type.
See Chapter 3, "Parts listing," on
page 27 for details of supported
DIMMs.
Chapter 5. Diagnostics and troubleshooting
81