Table 21. BMC firmware messages (continued)
Message
Severity
Proc/IO module 1
Error
(IO Bridge 1 Chip)
temperature over
non-recoverable
threshold.
Proc/IO module 2
Error
(IO Bridge 2 Chip)
temperature over
non-recoverable
threshold.
CPU 1 internal fault Error
CPU 2 internal fault Error
CPU 1 Fault + "Init
Error
Failed #x" where x
is the number of the
error condition
CPU 2 Fault
Error
Event
IBM PowerXCell 8i companion
chip 1 Temp above Shut-Off
Temperature (100°C)
IBM PowerXCell 8i companion
chip 2 Temp above Shut-Off
Temperature (100°C)
IBM PowerXCell 8i events
Processor Failure IBM
PowerXCell 8i processor 1
(Checkstop)
Processor Failure IBM
PowerXCell 8i processor 2
(Checkstop)
Failure Initializing IBM
PowerXCell 8i processor 1 or
IBM PowerXCell 8i companion
chip 1
Failure Initializing IBM
PowerXCell 8i processor 2 or
IBM PowerXCell 8i companion
chip 2
Automatic Action by
BMC
Power Off
The temperature of the
system board has reached
a critical level.
Power Off
The temperature of the
system board has reached
a critical level.
Reboot
Reboot
Power Off
Power Off
Chapter 5. Diagnostics and troubleshooting
Action required by
user
v Check that the
BladeCenter unit
cooling system is
operating correctly.
v Replace any
missing filler
blades in the
BladeCenter unit.
v Replace any
missing filler
blades in the
BladeCenter QS22
DIMM module
sockets.
v Check that other
blade servers are
operating within the
recommended
temperature range.
v Remove and
replace the blade
server, power on
and boot.
If problem persists,
please contact IBM
service.
There may be a
problem with the
system board. If
problem persists,
please contact IBM
service.
There may be a
problem with the
system board. If
problem persists,
please contact IBM
service.
Reboot. If the
problem persists, the
blade needs to be
replaced.
103