IBM QS22 - BladeCenter - 0793 Service Manual page 78

Problem determination and service guide
Hide thumbs Also See for QS22 - BladeCenter - 0793:
Table of Contents

Advertisement

Table 5. System board LEDs (continued)
LED
Light path LEDs
DIMM at I/O BUF 1
error
DIMM at I/O BUF 2
error
System DIMM1 error
System DIMM2 error
System DIMM3 error
System DIMM4 error
System DIMM5 error
System DIMM6 error
System DIMM7 error
System DIMM8 error
Light box LEDs
60
BladeCenter QS22 Type 0793: Problem Determination and Service Guide
Board
Color
location Explanation
Yellow
DS9
Yellow
DS10
Yellow
DS1
Yellow
DS2
Yellow
DS3
Yellow
DS4
Yellow
DS1
Yellow
DS6
Yellow
DS7
Yellow
DS8
There has been a failure in the I/O
DIMM module.
See Figure 27 on page 59 for the
location of each DIMM and its
associated LED.
There has been a failure in the
system DIMM module.
See Figure 27 on page 59 for the
location of each DIMM and its
associated LED.
Comments
Either remove or replace the
faulty DIMM. Note that if you
remove one I/O buffer DIMM
you must remove the other.
Reboot.
Either remove or replace the
faulty DIMM and reboot. See
"Adding or changing I/O
buffer DDR2 memory
modules" on page 41 for
supported memory
configurations.