1.
Ensure that:
• The software icons for HP Command View EVA
HP Storage System Scripting Utility
• The software is available from the Start menu (for example, Start > Programs > HP Command
View EVA).
• Go to Add/Remove Programs and make sure the applicable software components are listed:
• HP StorageWorks Command View EVA software suite
• HP StorageWorks Command View EVA
• HP StorageWorks Command View EVA Performance Monitor
• HP StorageWorks SMI-S EVA
• HP StorageWorks SMI-S CIMOM
NOTE:
HP Storage System Scripting Utility is not listed in Add/Remove Programs.
2.
Run HP Command View EVA.
3.
Verify the display of storage system resources in the interface. In the Navigation pane, click
Hardware and verify the following:
• New, uninitialized arrays appear as uninitialized storage systems.
• Previously initialized arrays appear with their previous names and correct status. (Select each
storage array to view the Properties window.)
• Previous disk groups, hosts, virtual disks, and other resources appear in the Navigation pane.
If information is not displayed properly, it may be necessary to configure your browser settings. See
HP StorageWorks Command View EVA installation guide for more information.

Upgrading the management module

If you have an EVA4400, follow the procedures in this section to:
Upgrade HP Command View EVA on the management module (for array-based management)
Upgrade the management module software
NOTE:
Management module software is bundled with the array-based management version of HP Command
View EVA. Thus, when you upgrade HP Command View EVA on the management module, you are
also upgrading the management module software.
Even if you are not using array-based management, you must complete the procedure in this section
for the EVA4400 to ensure the management module software is current.
Estimated time to complete: 25 minutes
When to perform: Any time prior to the upgrade.
To upgrade the management module:
HP StorageWorks Enterprise Virtual Array updating product software guide (XCS 09522000)
, HP Command View EVAPerf
appear on the desktop.
, and/or
39