Solving Security Credentials Configuration Problems; Possible Causes And Corrective Actions When No Storage System Found - HP 6400/8400 Software Manual

Hp storageworks enterprise virtual array updating product software guide (xcs 09522000) (576287-003, october 2010)
Hide thumbs Also See for 6400/8400:
Table of Contents

Advertisement

Corrective action
Table 10 Possible causes and corrective actions when no storage system found
The management server may not be able to
communicate with either controller.
When HP Command View EVA is first starting
up, a password may be enabled on the con-
trollers, but a password has not been entered
in HP Command View EVA.
The switches may not be correctly zoned,
making a storage system invisible to HP
Command View EVA.
HP Command View EVA may have been re-
started while there was a communication
failure between HP Command View EVA and
the controllers. When restart is completed,
the storage system that lost communication
will not be visible.
A storage system may not be visible to HP
Command View EVA because the controllers
are waiting for World Wide ID (WWID) to
be entered. This condition will occur if the
storage system has been uninitialized and
the cabinet is power cycled.
This may also occur if backend problems are
preventing access to the quorum drives. Once
communication is restored, the WWID along
with the checksum can be re-entered.

Solving security credentials configuration problems

The following Windows-based security groups are required on the management server:
NOTE:
Group names are case sensitive.
HP Storage Admins. To access all the features of HP Command View EVA, this security group is
required on the management server and must have at least one member (user account). Members
have view and manage capabilities.
HP Storage Users. Members have view capability only. This group is required only when a group
with extremely limited use of HP Command View EVA is required.
HP StorageWorks Enterprise Virtual Array updating product software guide (XCS 09522000)
Possible Cause
Check the connection configuration between the management server and
the controller pair. The management server must have a communication
path to both controllers in case one controller loses communications with
the server.
Enter the correct password through HP Command View EVA or disable
the password on the controller.
Verify that switches are zoned correctly.
1.
Verify that the controllers are up and functioning properly.
2.
Check the cable connections between the management server and
the switch.
3.
Verify that switch zoning is correct.
4.
Click Discover.
Enter the WWID.
Corrective Action
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 4400Storageworks 6400Storageworks 8400

Table of Contents