IBM 8646 - Eserver xSeries 220 Hardware Maintenance Manual page 101

Hardware maintenance manual
Table of Contents

Advertisement

Beep/Symptom
FRU/Action
3-1-3 (RAM test failed
1. DIMM
above address OFFFFH)
2. Memory card
3. System board
3-1-4 (Time-of-Day
1. Battery
clock failed)
2. System Board
3-2-1 (Serial port failed) 1. System board
3-2-2 (Parallel port
1. System board
failed)
3-2-4 (Failure
1. DIMM
comparing CMOS
2. Battery
memory size against
3. System board
actual)
3-3-1 (Memory size
1. DIMM
mismatch occurred, see
2. System board
"Memory Settings" on
3. Battery
page 32)
3-3-2 (Critical SMBUS
1. Disconnect the server power cord from outlet, wait 30 seconds and retry.
error occurred)
2. Unplug power, check for broken pins, and retry after reseating I2C cables between:
3. System Board
4. DIMMs
5. Power Supply
6. I2C Cable
3-3-3 (No operational
1. Install or reseat the memory modules, then do a 3 boot reset. (See "Using the
memory in system)
2. DIMMs
3. System Board
4-4-4 (I2C cable
1. Verify correct cable installation.
attached, system
2. Verify optional system management adapter is correctly installed in PCI slot 2.
management adapter
3. System management adapter.
not functioning)
Two Short Beeps
1. Run Diagnostics
(Information only, the
2. Run Configuration/Setup
configuration has
changed)
Three Short Beeps
1. DIMM
2. System Board
One Continuous Beep
1. Processor
2. Optional Processor (if installed)
3. System Board
Repeating Short Beeps 1. Keyboard
2. System Board
One Long and One
1. Video adapter (if present)
Short Beep
2. System Board
a. system management adapter (PCI slot 2/J31) and planar (J32);
b. DASD I2C on planar (J43) and DASD backplane
Configuration/Setup Utility program" on page 29.)
93
Symptom-to-FRU index

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver xseries 220 type 8646

Table of Contents