Appendix A: Integration and Usage Tips

This section provides a list of useful information that is unique to the Intel
SR1530CL/SR1530HCL/SR1530HCLS and should be kept in mind while integrating and server
system.
Only low-profile (1.2 inch or 30.48 mm) FBDIMMs can be used in the server systems.
Processor fans are not needed and are not supported. The system fan blowers and
power supply fans provide the necessary cooling needed for the system. Using a
processor fan in these systems may cause Intel
incorrectly monitor the system fans.
The air duct must be used to maintain system thermals.
System fan blowers are not hot swappable
A screw on the front edge of the top cover is required when the unit is installed in a user-
accessible environment.
The FRUSDR utility must be run to load the proper sensor data records for the server
system onto the server board.
Make sure the latest system software is loaded. This includes system BIOS, FRUSDR,
and BMC firmware. The latest system software can be downloaded from
http://support.intel.com/support/motherboards/server/S5000VCL/
Revision 2.2
®
System Management Software to
Intel order number D71005-005
Appendix A: Integration and Usage Tips
®
Server Systems
41