Power/Sleep Led; System Status Led; Table 18. Ssi Power Led Operation; Table 19. Control Panel Led Operation - Intel SR1530CLR - Server System - 0 MB RAM Technical Specification, Installation And Operation Manual

Server systems
Hide thumbs Also See for SR1530CLR - Server System - 0 MB RAM:
Table of Contents

Advertisement

Front Control Panel
The current limiting resistors for the power LED, the system fault LED, and the NIC LEDs are
®
located on the Intel
Server Board S5000VCL.
5.1.1

Power/Sleep LED

State
Power Mode
Power Off
Non-ACPI
Power On
Non-ACPI
S5
ACPI
S4
ACPI
S3-S1
ACPI
S0
ACPI
Note:
1.
The blink rate is ~ 1Hz with at 50% duty cycle.
5.1.2

System Status LED

Color
State
Off
N/A
Not ready
Green
Solid on
Ok
Green
Blink
Degraded
24

Table 18. SSI Power LED Operation

LED
Off
System power is off, and the BIOS has not initialized the chipset.
On
System power is on, but the BIOS has not yet initialized the chipset.
Off
Mechanical is off, and the operating system has not saved any context
to the hard disk.
Off
Mechanical is off. The operating system has saved context to the hard
disk.
1
Slow blink
DC power is still on. The operating system has saved context and
gone into a level of low-power state.
Steady on
System and the operating system are up and running.

Table 19. Control Panel LED Operation

Criticality
System not ready: Post error/NMI event/PCI or terminator missing
System booted and ready
System degraded
Unable to use all of the installed memory (more than one DIMM
installed).
Correctable errors over a threshold of 10 and migrating to a spare
DIMM (memory sparing). This indicates that the user no longer
has spared DIMMs indicating a redundancy lost condition.
Corresponding DIMM LED should light up.
In mirrored configuration, when memory mirroring takes place and
system loses memory redundancy.
Redundancy loss such as power-supply or fan. This does not
apply to non-redundant sub-systems.
PCI-e link errors
CPU failure/disabled – if there are two processors and one of
them fails
Fan alarm – Fan failure. Number of operational fans should be
more than minimum number needed to cool the system
Non-critical threshold crossed – Temperature and voltage
Intel order number D71005-005
Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS
and SR1530CLR/SR1530HCLR/SR1530HCLSR
Description
Description
Revision 2.2

Advertisement

Table of Contents
loading

Table of Contents