Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS
and SR1530CLR/SR1530HCLR/SR1530HCLSR

Figure 11. Fan Module Assembly - SR1530HCL/SR1530HCLR (SATA) and

Fan
System fan blower 1
System fan blower 2
PCI cooling fan
(SR1530CL only)
3.1

Power Supply Fans

The power supply supports two non-redundant 40 mm fans. They are responsible for the
cooling of the power supply, first hard drive bay, and slimline drive bay.
3.2

Processor Air Duct and Air Baffle

The system requires the use of a processor air duct and power supply/electronics bay isolation
air baffle to direct airflow and sustain appropriate air pressure.
An air baffle isolates the air flow of the two power supply fans from that of the system fan
module. The baffle is mounted into three stand-offs with one end fitting under the back edge of
the hard drive bay.
Revision 2.2
A
B
SR1530HCLS/SR1530HCLSR (SAS)

Table 14. Cooling Zones

Cooling
Zone
CPU1
Primary cooling for CPU1 and the system memory
CPU2
Primary cooling for hard HDD1, CPU2, the MCH, and the
low-profile PCI cards
PCI
Primary cooling for HDD0, full-height PCI cards, PXH and
the IOP80333 chipset
Intel order number D71005-005
AF001648
Greatest Cooling Influence
Cooling Sub-System
15