Intel® Server System SR2612UR TPS

Appendix A: Integration and Usage Tips

This section provides a list of useful information unique to the Intel
and should be kept in mind while integrating and configuring your Intel
Only low-profile (1.2 in or 30.48 mm) DIMMs can be used in the server system.
Processor fans are not supported and are not needed in the server system. The system
fan module and power supply fans provide the necessary cooling needed for the system.
Using a processor fan in this system may cause Intel
incorrectly monitor the system fans.
The CPU air duct must be used to maintain system thermals.
To maintain system thermals, all hard drive bays must be populated with either a hard
drive or drive blank.
System fans are not hot-swappable
Use of the screw found on the back edge of the top cover is required when the unit is
installed in a user-accessible environment.
The FRUSDR utility must be run to load the proper Sensor Data Records for the server
chassis onto the server board.
Make sure the latest system software is loaded on the server. This includes system
BIOS, FRUSDR, Integrated BMC firmware, and hot-swap controller firmware. You can
download the latest system software from the following website:
http://support.intel.com/support/motherboards/server/s5520ur/
Revision 1.3
Intel order number E76293-003
Appendix A: Integration and Usage Tips
®
Server System SR2612UR
®
Server Board S5520UR.
®
System Management Software to