Fire Zone Wiring; Links Zone Wiring; Keypad Zones - DSC CLASSIC PC585 Installation Manual

Software version 2.3 / dls-1 v6.7 and up
Hide thumbs Also See for CLASSIC PC585:
Table of Contents

Advertisement

NOTE: This option can only be selected if Normally Closed
(NC) detection devices or contacts are being used.
NOTE:Only one NC contact can be connected to each zone.
Wiring multiple detection devices or contacts on a single loop
is not allowed.
The following chart shows zone status under certain condi-
tions:
Loop Resistance
0 (shorted wire, loop shorted)
5600 (contact closed)
Infinite (broken wire, loop open)
11200 (contact open)
End of Line Resistors. . . . . . . . . . . . . . . . . . Section [013]: [1]
Double End of Line Resistors . . . . . . . . . . . Section [013]: [2]
2.9

Fire Zone Wiring

NOTE:4-Wire Smoke Detectors
All fire zones must be wired according to the following dia-
gram:

2.10 LINKS Zone Wiring

LINKS Support
When using the LINKS1000
cellular communicator, con-
nect the LINKS to the main
panel according to the fol-
lowing diagram:
6
LINKS Supervision (24 Hour Supervisory)
When
LINKS1000 cellular com-
municator, any main board
zone may be configured
for LINKS Supervision. Pro-
gram this zone as zone
type [09], 24 Hour Supervi-
Loop Status
sory in section [001].
Fault
With a LINKS Supervisory
Secure
zone, if the LINKS1000
experiences a trouble, the
Tamper
zone will be violated, caus-
Violated
ing the panel to report the
event to the central station.
This type of zone always
requires
resistor (5600 ).
Wire this zone according to the above diagram.
LINKS Answer
When using the LINKS1000
cellular communicator, any
main board zone may be
configured
Answer.
A
LINKS
downloading to be per-
formed in the event of tele-
phone line failure. When
the LINKS receives a tele-
phone call, it will activate
the RING terminal on the
LINKS circuit board. The
zone
LINKS
requires a single EOL resis-
tor (5600 ).
Wire the LINKS Answer zone according to the above diagram.
NOTE: The LINKS Answer zone is only required for download-
ing to the panel via the LINKS.
NOTE: When using the LINKS, Busy Tone Detection must not
be used.
NOTE: Keypad zones cannot be used for 24 Hour Supervisory
or LINKS Answer.

2.11 Keypad Zones

Each "z" keypad on the system has a zone input to which a
device - such as a door contact - can be connected. This
eliminates the need to run wires back to the control panel for
every device.
To install the keypad, open the keypad plastic by removing the
screw at the bottom of the unit. Locate the five terminals on
the keypad circuit board. Connect the four Keybus wires from
the control panel: the red wire to R, the black to B, the yellow
to Y and the green to G.
To connect the zone, run one wire to the Z terminal and the
other to B. For powered devices, use red and black to supply
power to the device. Run the red wire to the R (positive) termi-
nal and the black wire to the B (negative) terminal.
When using end of line supervision, connect the zone accord-
ing to one of the configurations outlined in section 2.8 "Zone
using
the
a
single
EOL
for
LINKS
zone
configured
for
Answer
allows
programmed
as
Answer
always