G e t t i n g
S t a r t e d :
2 . 1 1
K e y p a d
Z o n e s
Wiring" . End of line resistors must be placed on the device
end of the loop, not at the keypad.
NOTE: Keypad zones do not support DEOL resistors.
Assigning Keypad Zones
When using keypad zone inputs, each input used must be
assigned a zone number in Installer's Programming.
First, ensure that you have enrolled all installed keypads into
the desired slots. (See 2.5 "Keypad Assignment" on page 4.)
Next, enter programming section [020] to assign the zones.
There are eight programming locations in this section, one for
each keypad slot. Enter a 2-digit zone number for each of the
keypad zones. This number must be entered in the location
corresponding to the keypad to which each zone is con-
nected.
Example: The zone on an LCD5500Z keypad in slot 8 is to be
assigned zone 3. In section [020], scroll to option [8] and
enter (03).
NOTE:Keypad zones 1-4 will replace zone terminals Z1-Z4 on
the control panel.
NOTE: Once the keypad zones are assigned, you must also
program zone definitions and zone attributes. (See also 5.4
"Assigning Keypad Zones" on page 17).