Keypad Programming
[000]
Keypad Enrollment
NOTE: This must be done at each keypad requiring programming.
[0] Slot [Valid entries are 11-18; i.e. enter [11] for slot 1, [12] for slot 2, etc.]
[1] Function Key 1 Assignment (Valid entries are 00-17)
[2] Function Key 2 Assignment (Valid entries are 00-17)
[3] Function Key 3 Assignment (Valid entries are 00-17)
[4] Function Key 4 Assignment (Valid entries are 00-17)
[5] Function Key 5 Assignment (Valid entries are 00-17)
Function Key Options:
00 Null Key
01 For future use
02 For future use
03 Stay Arm
04 Away Arm
05 [*][9] No-Entry Arm
06 [*][4] Chime On / Off
07 [*][6][——][4] System Test
Slot
LED Defaults
11
LCD Defaults
18
KEYPAD 1
I________I________I
KEYPAD 2
I________I________I
KEYPAD 3
I________I________I
KEYPAD 4
I________I________I
KEYPAD 5
I________I________I
KEYPAD 6
I________I________I
KEYPAD 7
I________I________I
KEYPAD 8
I________I________I
Basic Programming
Zone Definitions
00 Null Zone (Not Used)
01 Delay 1
02 Delay 2
03 Instant
04 Interior
05 Interior, Stay/Away
06 Delay, Stay/Away
07 Delayed 24 Hour Fire (Hardwired)
08 Standard 24 Hour Fire (Hardwired)
09 24 Hour Supervisory
NOTE:Keypads must be installed to use 24-hour Buzzer zones.
NOTE:Keypad zones are assigned in section [020]. Zone Attributes are assigned in sections [101] - [132]. Zone assignment is in
sections [202] - [205].
[001] Zone 1-8 Definitions
Default
01
Zone 1
I_______I_______I
03
Zone 2
I_______I_______I
04
Zone 3
I_______I_______I
04
Zone 4
I_______I_______I
30
(Section 2.5 "Keypad Assignment" on page 4)
08 [*][1] Bypass Mode
09 [*][2] Trouble Display
10 [*][3] Alarm Memory
11 [*][5] User Programming
12 [*][6] User Functions
13 Command Output #1 [*][7][1]
14 Command Output #2 [*][7][2]
15 For future use
Function
Function
Key 1
Key 2
03
04
03
04
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
10 24 Hour Supervisory Buzzer
11 24 Hour Burglary
12 24 Hour Holdup
13 24 Hour Gas
14 24 Hour Heating
15 24 Hour Medical
16 24 Hour Panic
17 24 Hour Emergency
18 24 Hour Sprinkler
19 24 Hour Water
(Section 5.2 "Zone Programming" on page 15)
Default
00
I_______I_______I
00
I_______I_______I
00
I_______I_______I
00
I_______I_______I
16 [*][0] Quick Exit
17 [*][1] Reactivate Stay/Away's
18 For future use
19 For future use
20 For future use
21 For future use
Function
Key 3
06
06
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
20 24 Hour Freeze
21 24 Hour Latching Tamper
22 Momentary Keyswitch Arm
23 Maintained Keyswitch Arm
24 LINKS Answer
25 Interior Delay
87 Delay 24 Hour Fire (Wireless)
88 Standard 24 Hour Fire (Wireless)
Zone 5
Zone 6
Zone 7
Zone 8
Function
Function
Key 4
Key 5
14
16
14
16
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I
I________I

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic pc585

Table of Contents