Keypad Sounder Control
You can select from 21 different keypad tones. Use the arrow
keys (< >) to scroll to the desired keypad sound level and
press [#] to exit. This feature can be accessed on LED key-
pads by pressing and holding the [*] key.
[*][7] Command Output Functions
The user can activate programmable output functions using
the [*][7][1-2] commands. The outputs may be activated when
the system is either armed or disarmed.
[*] [7] [1] – Command Output Option #1:
Press [*] [7] [1] [Access Code, if required] to activate outputs
programmed as PGM output option [19]. This output can be
used for operating devices such a garage door opener, light-
ing or door strikes.
[*][7][2] – Command Output Option #2:
Press [*][7][2][Access Code, if required] to activate all outputs
programmed as one of PGM output options [03] or [20].
Special Note: Traditionally, [*][7][2] has been reserved for
resetting smoke detectors. Smoke detectors should now be
programmed as output [03] "Sensor Reset" . If using output
option [03], do not program [20] Command Output Option #2.
Please see 5.11 "PGM Output Options" on page 21 for more
information.
[*][8] Installer's Programming
Enter [*][8] followed by the Installer's Code to access
Installer's Programming. See sections 4 and 5 for more infor-
mation.
[*][9] Arming Without Entry Delay
When the system is armed with the [*][9] command, the panel
will cancel the entry delay. Delay 1 and Delay 2 type zones will
be instant and Stay/Away zones will be bypassed as soon as
the exit delay has ended (see section 5.2 "Zone Program-
ming" on page 15). The user must enter a valid access code
after pressing [*][9].
[*][0] Quick Arm
If the Quick Arm option is enabled (section [015], option [4]),
enter [*][0] to arm the panel without an access code. (See
5.17 "Arming/Disarming Options" on page 24.) If the Quick
Arm option is disabled, users will need to enter an access
code after pressing a function key.
NOTE: Quick Arm cannot be used to cancel auto arm.
[*][0] Quick Exit
The Quick Exit function, if enabled, will allow someone to
leave an armed premises through a Delay type zone without
having to disarm and re-arm the system. (See 5.17 "Arming/
Disarming Options" on page 24.)
When [*][0] is entered, the panel will provide a two minute win-
dow for the user to exit the premises. During this time, the
panel will ignore only one activation of a Delay zone. When the
Delay zone is secured, the panel will end the two minute quick
exit delay.
If a second Delay zone is tripped, or if the zone is not restored
after two minutes, the panel will begin entry delay 1.
NOTE: If the Exit Delay is in progress, performing a Quick Exit
will not extend the Exit Delay.
3.5

Function Keys

There are five function keys on each keypad labelled Stay,
Away, Chime, Reset and Exit. Each of these keys is pro-
grammed by default to perform one of the functions described
K e y p a d
C o m m a n d s :
below. Press and hold the appropriate key for two seconds to
activate a function.
If the Quick Arm option is disabled (section [015], option [4]),
users will need to enter an access code after pressing a func-
tion key.
NOTE:On the PC1555RKZ keypad, use number keys 1 - 5 for
the function keys.
"Stay" – (03) Stay Arm
The system will arm in the Stay mode (see 3.2 "Auto Bypass –
Stay Arming" on page 8). Enable the Quick Arm feature (pro-
gramming section [015], option [4]) to have this key function
without the need to enter an access code. If Quick Arm is not
enabled, the user will have to enter an access code before the
system will stay arm.
"Away" – (04) Away Arm
The system will arm in the Away mode (see 3.2 "Auto Bypass
– Stay Arming" on page 8). Enable the Quick Arm feature (pro-
gramming section [015], option [4]) to have this key function
without the need to enter an access code. If Quick Arm is not
enabled, the user will have to enter an access code before the
system will away arm.
When the panel is being Away armed, users can restart the
exit delay once, by pressing the Away button before the exit
delay expires. This will not work if the panel is being Stay
armed.
"Chime" – (06) Door Chime On / Off
The Door Chime feature will turn ON or OFF. (See "[*][4] Door
Chime On/Off" on page 9.)
"Reset" – (14) Sensor Reset or [*][7][2]
The panel will activate all PGM outputs programmed as option
[03] Sensor Reset or [20] Command Output Option #2. (See
"[*][7] Command Output Functions" .)
"Exit" – (16) Activate Quick Exit
The panel will activate the Quick Exit feature (See "[*][0]
Quick Exit" on page 11.)
Additional Function Key Options
The programming of any function key on any keypad may be
changed to one of the options listed below. (See 2.5 "Keypad
Assignment" on page 4 for instructions on changing function
key programming.) Each option is listed according to the pro-
gramming code, followed by the corresponding [*] key com-
mand. For more information regarding each function, please
refer to the appropriate part of Section 3.4, "[*] Commands".
NOTE: The PC5509 function keys cannot be changed from the
defaults listed above.
[00]
Null Key: The key is not used and will perform no
function when pressed.
[01]-[02] For future use
[03]
Stay Arm: As described above.
[04]
Away Arm: As described above.
[05]
[*][9] No-Entry Delay Arm: A valid access code
must also be entered.
[06]
[*][4] Door Chime On / Off: As described above.
[07]
[*][6][----][4] System Test: A valid master code must
also be entered.
[08]
[*][1] Bypass Mode: A valid access code may need
to be entered.
[09]
[*][2] Trouble Display
[10]
[*][3] Alarm Memory