[012] Keypad Lockout Options
NOTE:If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
Number of Invalid Codes Before Lockout (001-255 codes)
I_______I_______I_______I
000
Lockout Duration (001-255 minutes)
I_______I_______I_______I
[013] First System Option Code
Default
Option
OFF
1
I________I
OFF
2
I________I
ON*
3
I________I
OFF
4
I________I
OFF
5
I________I
ON
6
I________I
ON
7
I________I
OFF
8
I________I
* Option 3 must be OFF if LCD keypads older than v2.0 are used.
[014] Second System Option Code
Default
Option
OFF
1
I________I
OFF
2
I________I
OFF
3
I________I
OFF
4
I________I
OFF
5
I________I
ON
6
I________I
OFF
7
I________I
OFF
8
I________I
[015] Third System Option Code
Default
Option
ON
1
I________I
OFF
2
I________I
OFF
3
I________I
ON*
4
I________I
OFF
5
I________I
OFF
6
I________I
ON
7
I________I
OFF
8
I________I
* When using a PC5132 version 2.1 or older with WLS909 Wireless Keys, option [4] must be ON for the Arm button to work.
[016] Fourth System Option Code
Default
Option
ON
1
I________I
OFF
2
I________I
OFF
3
I________I
OFF
4
I________I
ON
5
I________I
OFF
6
I________I
OFF
7
I________I
OFF
8
I________I
32
(Section 5.21 "Keypad Lockout Options" on page 25)
ON
Normally Closed Loops
Double End-of-Line Resistors
Panel shows all troubles when armed
Tampers/Faults do not show as open
For future use
Audible Exit Fault Enabled
Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown
Temporal Three Fire Signal Enabled
ON
Arm / Disarm Bell Squawk enabled
Bell Squawk During Auto Arm
Bell Squawk On Exit Delay
Bell Squawk On Entry Delay
Bell Squawk On Trouble
Audible Exit with Urgency
Exit Delay Termination Enabled
Fire Bell is Continuous
ON
Fire Keys Enabled
Panic Keys Audible (Bell / Beeps)
Quick Exit Enabled
Quick Arming Enabled
Code Required For Bypassing
Master Code Not Changeable
TLM Enabled
TLM Audible (Bell) When Armed
ON
AC Trouble Displayed
Trouble Light Flashes if AC Fails
Blank Keypad When Not Used
Code Required to Remove Kypd BlankingNo Code Required
Keypad Backlighting is enabled
Power Save Mode enabled
Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed
Keypad Tampers enabled
Off
End-of-Line Resistors
Single End-of-Line Resistors
Panel shows only Fire troubles when armed
Tampers/Faults show as open
Audible Exit Fault Disabled
Standard Pulsed Fire Signal
Off
Arm / Disarm Bell Squawk disabled
No Bell Squawk During Auto Arm
No Bell Squawk On Exit Delay
No Bell Squawk On Entry Delay
No Bell Squawk On Trouble
Silent Exit Delay
Exit Delay Termination Disabled
Fire Bell Follows Bell Cut-off
Off
Fire Keys Disabled
Panic Keys Silent
Quick Exit Disabled
Quick Arming Dis. / Function keys Req. Code
No Code Required
Master Code Changeable
TLM Disabled
TLM Trouble Beeps When Armed
Off
AC Trouble Not Displayed
Trouble Light Does Not Follow AC Status
Keypad Active Always
Keypad Backlighting is disabled
Power Save Mode disabled
Keypad Tampers disabled
Section Page #
2.8
5
2.8
5
3.4
8
3.4
8
5.18
24
5.20
25
5.13
23
Section Page #
5.17
24
5.18
24
5.18
24
5.18
24
3.4
8
5.18
24
5.18
24
5.13
23
Section Page #
5.16
23
5.16
23
3.4
8
3.4
8
3.4
8
5.1
15
5.12
23
5.12
23
Section Page #
3.4
8
3.4
8
5.22
25
5.22
25
5.23
25
5.22
25
5.17
24
5.25
26

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic pc585

Table of Contents