Setting A Baseline; Displaying Counters And Time Intervals; Output Filtering - Juniper PHYSICAL LAYER - CONFIGURATION GUIDE V11.1.X Configuration Manual

Junose software for broadband services routers
Table of Contents

Advertisement

Setting a Baseline

You can set a statistics baseline for serial interfaces, subinterfaces, and/or circuits
using the baseline interface serial command. Use the delta keyword with the show
commands to display statistics with the baseline subtracted.

Displaying Counters and Time Intervals

Counters and time intervals are MIB statistics, which are defined in the following
specifications:
The show controllers t3 slot/port all command displays the following information:
The show controllers t3 slot/port: channel all command displays the following
information:

Output Filtering

You can use the output filtering feature of the show command to include or exclude
lines of output based on a text string you specify. See Command Line Interface in
JUNOSe System Basics Configuration Guide, for details.
baseline interface serial
host1#show controllers t3 serial 0/1
RFC 2495 Definitions of Managed Objects for the DS1, E1, DS2 and E2 Interface
Types (January 1999)
RFC 2496 Definitions of Managed Objects for the DS3/E3 Interface Types
(January 1999)
T3 current interval counters Counters for the current interval
T3 last interval counters Counters for the previous interval
T3 24-hour total counters Cumulative counters for the last 24 hours or since
the interface was started
The last 24 hours of 15-minute reporting intervals (96 intervals)
T1 current interval counters Counters for the current interval
T1 last interval counters Counters for the previous interval
T1 24-hour total counters Cumulative counters for the last 24 hours or since
the interface was started
The last 24 hours of 15-minute reporting intervals (96 intervals)
Use to set a statistics baseline for serial interfaces.
The router implements the baseline by reading and storing the statistics at the
time the baseline is set and subtracting this baseline whenever baseline-relative
statistics are retrieved.
Chapter 1: Configuring Channelized T3 Interfaces
Monitoring Interfaces
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

E series

Table of Contents