Usb Settings - HP 630n - JetDirect Gigabit EN Print Server Administrator's Manual

Jetdirect print servers
Hide thumbs Also See for 630n - JetDirect Gigabit EN Print Server:
Table of Contents

Advertisement

Table 4-14
LPD Queues tab settings (continued)
Item
Instructions for setting up an LPD printer are different for different operating systems. See
on page 155
Example To reset an LPD printer at the start of each print job, you can create a print queue named
clear_printer that issues a PCL reset command (Escape-E) at the beginning of each job.
First, set up the print queue:
a.
Name the string: Type reset_string into the String Name field in row 1.
b.
Define the string's value: Type "\1BE" (Escape-E) into the Value field in row 1. (Alternatively, you
could type "\1B\45".)
c.
Name the queue: Type clear_printer into the Queue Name field in row 5.
d.
Set up the prepend string: Type reset_string into the Prepend String field in row 5.
e.
Leave the Append String field in row 5 blank.
f.
Set the queue type: Set the Queue Type field in row 5 to RAW.
Then, set up the printer to use the queue, making sure to specify clear_printer when asked for a queue
name. (For details about setting up the printer, see
sent to the printer either from the server or from a client computer that has set up that printer, includes
a reset command at the beginning of the job.

USB Settings

If the HP Jetdirect external print server provides a USB connection to the network device (such as a
USB printer), a link to USB configuration parameters is displayed.
Table 4-15
USB Settings tab
Item
USB Speed
ENWW
Description
Character values can be in the extended ASCII range of 0 to 255 (hex 00 to FF). You can
specify a non-printing character using its hexadecimal value by entering a backslash (\) followed
by two hexadecimal characters. For example, to enter the escape character (hex 1B), type
"\1B". If your string includes the back slash character itself, specify it as "\5C". Enter up to 240
characters in this field. The characters in the field are checked for hexadecimal values,
converted if necessary, and stored internally. The maximum number of characters stored
internally in the string is 80; any characters that exceed this are discarded.
for details.
Description
(Read-only parameter, for USB 2.0 print servers only.) The auto-negotiated
communication speed over the USB connection between the print server and the device.
Full Speed 12 Mbits/sec as specified in the USB v2.0 specifications, compatible with
USB v1.1 specifications.
Hi-Speed 480 Mbits/sec for USB v2.0 devices only.
Disconnected USB port is not connected.
LPD printing on page
155.) After that, any print jobs
LPD printing
Networking tab
83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents